Predbat-led EV charger control: shared mixin, Octopus Intelligent rule and guest charging for GE, Ohme and Zappi (folds #5284 + #5311) - #5448
Merged
Conversation
Ohme, myenergi and GivEnergy EVC each carry their own copy of the same control loop. CarChargerControl owns it once: read the per-car plan, charge inside a window and stop outside one, re-apply on drift, and release on read only or when the control switch is turned off, with the switch persisted across restarts. Components supply only the charger-specific send, release, connected and drift checks. Nothing uses it yet; the components move onto it in following commits. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
GivEnergy EVC control moves onto CarChargerControl. The component keeps what is GivEnergy's own: which chargers exist and in what order, whether a car is connected, and the start-charge / stop-charge commands. Behaviour is unchanged: the switch keeps its storage key, chargers without a car are still left alone, and release still only restarts a charger Predbat had stopped. The EVC read only check now falls back to the set_read_only arg, like the other chargers, rather than the switch entity; the fallback only applies before Predbat sets the attribute at startup. The test double's get_arg answers set_read_only from the same flag as its switch, as Predbat does. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Zappi control moves onto CarChargerControl. The component keeps what is myenergi's own: Fast inside a window and Stopped outside one, drift detected from the polled mode, and release back to the saved mode or Eco+. One deliberate change: a Zappi with no car to follow (more Zappis than num_cars, briefly true while auto-config's num_cars reaches the base) is now left alone rather than Stopped, matching what GivEnergy EVC control already did. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Ohme control moves onto CarChargerControl. The component keeps what is Ohme's own: max charge inside a window and pause outside one, drift detected from the session mode, and release back to Ohme's smart schedule with the user's target percent restored. Ohme has no control switch, so read only stays the only release. Its inline plan parser goes too, in favour of the shared one. That fixes a New Year case the copy missed: read just after midnight on 1 January, a window that started on 31 December parsed as the following December, so a charge running across midnight was paused. A release Ohme refuses is now retried on the next control cycle rather than attempted once, so a paused car is not stranded by one failed call. The control tick is wrapped the way myenergi's already is: a refused command logs a warning instead of failing the whole run, which would otherwise repeat every minute while read only stays on. The mixin now checks for a switch before touching storage, so a component with no switch never needs a storage attribute. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
… retry refused GE commands - A charger Predbat holds that falls beyond the cars it follows (num_cars dropped) was never commanded again, left charging or stopped with nobody in control. apply() now releases it. - GivEnergy's async_send_evc_command() reports a refusal by returning None, so a refused release was taken as done and a stopped charger stranded - the failure the Ohme and myenergi retries already close. GE charger control now raises EVCCommandFailed on a refusal, so the command is not recorded and is tried again next cycle; GE's run loop catches it as a warning, as Ohme's and myenergi's already do. A refused start or stop is retried the same way rather than recorded as sent. - Docstring for a nested test helper. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…eased Zappi forgets its mode Found by a later review, in code from this PR: - Releasing, releasing a charger whose car has gone, and driving from the plan ran as one loop, so the first charger to refuse a command stopped every charger after it - and each cycle retried in the same order, so they stayed blocked. With two Zappis held Stopped and read only on, a refusing Zappi 1 left Zappi 2 Stopped for good. Each charger is now handled on its own; the first failure is still raised after the rest have had their turn, for the run loop to log and retry. A charger is forgotten as soon as its own release goes through, so a retry re-sends only to the one that refused. - A Zappi released on its own (its car gone when num_cars dropped) kept its saved mode, so taking it back later saved nothing new and the next release restored the stale mode. The saved mode is now dropped once that Zappi's release goes through. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…arger Charger control now decides per car whether Octopus Intelligent is in charge of the charger. Where Octopus delivers its dispatches by driving the charger itself, Predbat leaves it alone - releasing it if it was holding it - so the two never fight. Where Octopus drives the car, or there is no Intelligent car, Predbat drives the charger from the car slot sensor, which then carries the Octopus dispatches, so the car cannot charge outside them on its own timers. Octopus car N is the Nth wired Intelligent device, and the Octopus component already records whether each is a charge point. When that cannot be told - slots from outside the Octopus component, or before it has discovered its devices - the charger is left alone, unless the component's control setting is explicitly true. Nothing turns control on by default yet; that follows. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
ge_cloud_evc_control no longer defaults to false. Left unset, control follows ge_cloud_automatic_evc: setting that is the user asking Predbat to plan for the car, and it is what maps each charger to its car. An explicit false keeps control off, and only an explicit true warns when a prerequisite is missing. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
ohme_control no longer defaults to false. Left unset, control follows ohme_automatic, which registers the car. Where the Intelligent slots come from the Ohme, Octopus drives the charger and Predbat still leaves it alone - logged as Info for an unset control, and as a warning only when ohme_control was explicitly set true. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…tomatic myenergi_zappi_control no longer defaults to false. Left unset, control turns on only when the user wrote myenergi_automatic or myenergi_automatic_zappi into apps.yaml themselves. Both default on, so following their values alone - the rule GE and Ohme use - would switch every Zappi user to Predbat control on upgrade, and a Zappi held off between windows can no longer divert solar in Eco/Eco+. The options considered are recorded in enable_control()'s docstring for review. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
… Intelligent A new "Predbat starting and stopping your charger" section in car-charging.md sets out when each charger's control turns on while its setting is unset, the upgrade change for existing automatic users, and what happens on Octopus Intelligent depending on whether Octopus drives the charger or the car. The per-setting entries in apps-yaml.md and components.md now describe the unset default instead of false. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…er start a charge handing over Found by review before opening the stage 2 PR: - Read is_charger from the car's own wired octopus_intelligent_slot sensor instead of pairing car N with the Nth sorted Octopus device. Both the Octopus and Kraken components publish it there, so E.ON/EDF SmartFlex users are covered and a slot list in a different order can no longer pair a car with another car's device. - Only wait for Octopus discovery when the Octopus component runs its automatic setup. With octopus_automatic off it never wires the slots, so control never turned on. "Cannot tell yet" also gets its own log line rather than claiming the car is on IOG. - Handing a charger to Octopus no longer starts it. A normal release undoes a stop so a car is never stranded, but here Octopus decides when to charge: a GE charger Predbat stopped is left for Octopus, an Ohme has max charge turned off before it is resumed into its smart schedule, and a Zappi returns to its own mode, Eco+ in place of Fast. - The control settings have no default, which also skipped get_arg()'s boolean conversion, so a quoted "false" or a 0 read as set. parse_control_setting() normalises them to None, True or False in each component. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…imit are set Predbat drives an Ohme with max charge, which overrides the target set in the Ohme app, so car_charging_battery_size and car_charging_limit are all that stop a charge. Left at their defaults (100 kWh, 100%) the car would be charged to full. Unset ohme_control now waits for both to be in apps.yaml and logs why; an explicit ohme_control: true is still the user's call. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…opus Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…pus drives follows its dispatch sensor - switch.predbat_octopus_intelligent_charging only changes Predbat's own planning: Octopus goes on switching a charger that is its Intelligent device whatever the switch says. The device is now judged first, so turning the switch off no longer has Predbat fight Octopus for that charger. For a car Octopus drives, the switch still decides whether the charger follows the dispatches or Predbat's own plan. - Where Octopus drives the car, the charger also runs while the car's dispatch sensor is on. The plan carries the dispatches but is only republished every 5 minutes and leaves out a dispatch Octopus has not given any energy yet, so the charger held the car off for the first minutes of a new dispatch. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
While Predbat drives a charger it holds it off outside the planned windows, so a visitor's car could not charge - and stage 2 turns control on by default. Each component (GE, myenergi, Ohme) now publishes switch.predbat_<component>_guest_charging beside its control. On, Predbat releases the charger as it does for read only mode, so it runs on its own settings; how the guest charges is chosen on the charger itself. It turns itself off when a connected car is unplugged, on chargers that can tell (GE), and otherwise after GUEST_CHARGING_MAX_HOURS (12). It is deliberately not persisted, so a restart puts Predbat back in charge. The guest's charging is still counted as the car's. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…or Ohme Both report whether a car is plugged in - the Zappi's plug status, the Ohme's UNPLUGGED status - so guest charging now ends on unplug for every charger, not just GE. A new charger_control_car_plugged() hook carries it, separate from charger_control_connected(), so how Predbat drives an empty Zappi or Ohme is unchanged. An unknown plug state reads as plugged in, leaving the 12 hour limit. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…ends are judged by the clock Found by review before opening the stage 2 PR: - Guest charging ended on any unplug, including the owner's car being unplugged to make way for the guest. Only a car plugged in after the switch went on now ends it (empty, plugged in, empty again); a guest who plugged in first is left to the 12 hour limit or a manual off. - A GE status blip (offline, unavailable, unknown) read as an unplug and ended guest charging. Only "available" and "idle" count as empty now, as the Zappi and Ohme already treat unknown states as plugged in. - The charger followed the dispatch sensor's on/off state, which only refreshes every couple of minutes and so ran the charger past the end of a dispatch. The dispatch times on the sensor are now judged against the clock, in both the Octopus and the Kraken formats, falling back to the state for a sensor with no times. - A toggle on the guest switch now flips it rather than turning it off. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…rger A dispatch sensor that does not say which device Octopus drives (the Octopus Energy integration, for one) leaves the charger uncontrolled for good, and was only an Info line. It is now a warning naming the component's own setting to set true. Waiting for the Octopus component to discover its devices, which normally clears within a cycle or two, stays Info. Each reason is logged once, and again only when it changes. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…g a charger (#5311 review) Only the Octopus component was waited for. After a restart a Kraken (E.ON/EDF SmartFlex) user's charger could be driven before Kraken had wired octopus_intelligent_slot - stopping a GE charger mid-dispatch, which the hand-over on the next cycle then left stopped. Kraken wires its devices in its first successful run, from cache or fresh discovery, so until it has started the charger is left alone. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…it, and stop waiting on discovery after 15 minutes (#5311 review) - Cannot tell whether Octopus drives a charger: a charger Predbat had stopped was let go without being started, as if Octopus were taking it over. With nobody known to take it over, a GE charger was left stopped indefinitely. It is now released as usual; the non-starting hand-over is kept for a charger Octopus is known to drive. - Waiting for Octopus or Kraken discovery is bounded at 15 minutes. A Kraken component whose first run never succeeds (a failed login) otherwise left every unwired car's charger uncontrolled for good. The log line now names both components. - The apps.yaml default's literal "re:" string, before its regex matches, is no longer read as a dispatch sensor - which on every restart warned users with no Intelligent sensor to set a control override they do not need. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…at a discovery that never finishes as cannot tell (#5311 review) Releasing during discovery started a charge Predbat had stopped whenever the Octopus or Kraken component restarted, and driving the charger once the wait ran out could fight Kraken if it was the one driving it. While discovery is under way the charger is now left as it is and still held, so it is settled either way once discovery finishes. After 15 minutes Predbat still cannot tell, so it warns once and hands back a charger it holds, as for a dispatch sensor that does not say. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…r is known (#5311 review) The wait's start was only cleared when discovery was asked about with nothing discovering, which stops happening once every car's driver is known. A later component restart could then find the old start and count the wait as already over. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…its own schedule stays the car plan otherwise Main's #5401 now takes the car plan from Ohme's own schedule when Predbat is not controlling the charger, so a default user already gets a plan that matches what the charger will do. Turning control on by default would override that schedule - one the user may have set up deliberately - with max charge, which also overrides the Ohme app's target. ohme_control goes back to a false default; GE and Zappi keep their automatic defaults. The size and limit guard for an unset ohme_control goes, as there is no unset default any more. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…alone when Octopus drives the car, unless asked to follow it When the car itself is the Octopus Intelligent device, the car starts and stops its own charge. Predbat now leaves the charger alone by default, handing over a charger it held without starting a charge, as it does when Octopus drives the charger. The new expert-mode switch, default off, has Predbat drive the charger to the car's dispatches instead, so the car cannot also charge on its own timers. The Ohme follows the same switch: with it on, ohme_control can run while Octopus drives the car, where #5405 otherwise stands it down. A change of the switch is picked up on the next Ohme poll. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…llowing Predbat's own plan with Intelligent charging off, and log only real Ohme changes (#5311 review) - Octopus driving the car means nobody drives the charger, so a charger Predbat had stopped is released as usual (GE started, Zappi back to its own mode including Fast) rather than handed over without starting, which left it stopped through every dispatch. - With switch.predbat_octopus_intelligent_charging off Predbat plans the car itself, so it still drives the charger to that plan whatever the new switch says. - An Ohme poll that sees only the new switch change logs that change, and only re-decides control while Octopus drives another device - not the Octopus tariff change it used to report. - The log points at expert mode for the switch, and the class docstring says the charger is left alone by default. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…ging off while Octopus drives the car (#5311 review) The shared charger rule drives a charger for a car Octopus drives when switch.predbat_octopus_intelligent_charging is off, as Predbat then plans the car itself; the Ohme stood control down there regardless. It now follows the same rule, and re-decides when either switch changes. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…harger value as cannot tell (local review) Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Contributor
There was a problem hiding this comment.
🟡 Changes recommended
Ohme’s live Intelligent handoff uses the unsafe release order, and persistence failures can be silently ignored.
2 open findings
What changed in this PR
Introduces shared Predbat-led EV charger control for GivEnergy, Ohme, and myenergi, including automatic activation, Intelligent dispatch handling, and guest charging.
Changes:
- Adds the shared
CarChargerControlmixin. - Migrates three charger integrations and adds extensive tests.
- Updates configuration and user documentation.
| File | Description |
|---|---|
apps/predbat/car_charger_control.py |
Adds shared charger-control logic. |
apps/predbat/gecloud.py |
Migrates GivEnergy charger control. |
apps/predbat/myenergi.py |
Migrates Zappi charger control. |
apps/predbat/ohme.py |
Migrates Ohme control and Intelligent handling. |
apps/predbat/components.py |
Adds tri-state control configuration. |
apps/predbat/config.py |
Adds the follows-car switch. |
apps/predbat/unit_test.py |
Registers shared-control tests. |
apps/predbat/tests/test_car_charger_control.py |
Tests the shared mixin. |
apps/predbat/tests/test_ge_cloud.py |
Expands GivEnergy control tests. |
apps/predbat/tests/test_myenergi.py |
Expands Zappi control tests. |
apps/predbat/tests/test_ohme.py |
Expands Ohme control tests. |
docs/apps-yaml.md |
Documents automatic-control settings. |
docs/car-charging.md |
Documents Intelligent and guest charging. |
docs/components.md |
Updates component configuration guidance. |
tools/debug-journal.md |
Updates myenergi diagnostic notes. |
🧠 Review effort: Balanced
💡 Add a code-review agent skill or configure MCP servers for context-aware, tailored reviews. Learn more in the docs.
… when Storage refuses to save the control switch (#5448 review) Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
…charge Predbat started (#5448 review) Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
# Conflicts: # tools/debug-journal.md
…l review) The discovery wait was one clock shared by every car, and drive_one reset it whenever any car's driver was known. With two cars - one wired, one still waiting on a Kraken login that keeps failing - the wired car reset the clock every cycle, so the waiting car never reached "cannot tell" and its charger was held as it was indefinitely, with no warning. The clock is now kept per car, and still cleared for every car once discovery has finished. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…istence clause (#5448 review) The myenergi rename to charger_control_active caught the Sunsynk/Deye sentence too; those components still persist control_active. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…ed (#5448 review) charger_control_refresh_windows() only waited for any car's plan, so with car 0's slot sensor published and car 1's not, car 1 read as an empty plan and its charger was stopped. A car missing from charger_control_windows is now unknown: its charger is left as it is until its plan appears or an Octopus dispatch says to charge. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
… (local review) The unknown-plan skip came before the drift and last-state checks, so a charger a dispatch had started for a car with no published plan was frozen on once the dispatch ended. The skip now applies only to a charger Predbat does not hold. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…t (local review) A held charger whose car's planned attribute went missing for a cycle was driven from an empty window list and stopped mid-charge. The windows are absolute times, so the last ones read are carried forward instead. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…review) update_slot_mode() handed the charger back outside any handler, so an ApiException from Ohme skipped the session fetch, publish and slot wiring for every poll until Ohme accepted the command. It is now a warning, as in the control tick; the charger stays held and the next poll retries. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…ne through (local review) The mode was snapshotted ahead of set_mode, so a refused command left a snapshot for a Zappi Predbat never held. Release paths only run for held Zappis, so it could outlive the moment and be restored much later in place of what the user had set by then. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
publish_car_plan() built one plan list for every car, and handed the same list object to each slot sensor, so with two or more cars every sensor's 'planned' attribute held the windows of all of them. Pre-existing on main, but the shared charger control drives charger N from car N's 'planned', so a charger would start in another car's window. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…d has gone through (local review)" This reverts commit 3ff61b7. Snapshotting after set_mode traded one hazard for a worse one: a command that timed out but was applied is retried with the Zappi already Stopped, and Stopped was then saved as the user's mode, so a later release left the car unable to charge. Saving ahead of the command gets the mode the user really had; a snapshot left by a refused command is the lesser risk, and a full release still clears it. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…cal review) A saved Stopped is most likely Predbat's own hold: after a restart, or a Stop that timed out but was applied, the first snapshot is taken with the Zappi already Stopped. Restoring it left the car unable to charge, the very outcome a release exists to prevent. It now falls back to Eco+, as for no saved mode. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Conflict in apps/predbat/ohme.py (OhmeAPI.__init__): main's #5443 added slot_source/slot_source_applied (Octopus dispatch sensor read beside Ohme's planned slots); this branch added follows_car (Predbat drives the charger while Octopus drives the car). Independent state - kept both. The rest of update_slot_mode() and run() auto-merged with both changes intact. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…ests The tests main added in #5443 read OhmeAPI.control_active, which this branch renamed to charger_control_active when control moved into the shared CarChargerControl mixin. Only the attribute name changes; the assertions are unchanged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
… an Ohme claim Since #5443 the Octopus component keeps wiring its whole dispatch-sensor list into octopus_intelligent_slot while Ohme holds car_slot_owner (the claim now covers only the ready time and charge limit). The car_slot_owner shortcut in charger_control_octopus_drives_charger()/_drives_car() predates that and applied to every car, so with an Ohme on car 0 and a second car whose Intelligent device is the car itself, a Zappi or GE EVC on car 1 was left to Octopus: follows_car ignored, and a held charger handed over stopped. The sensor's own is_charger now decides; the claim only stands in when the sensor does not say (the Ohme's own slot sensor). drives_car no longer reads an "unknown" is_charger as "the car". Regression test fails on the merge without this change. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…he merge The previous commit let car 0's own dispatch sensor override an Ohme car_slot_owner claim. That changed behaviour the merge never touched: with ohme_automatic_octopus_intelligent forced on, or Octopus's device ids sorting the car's sensor first, a charger on car 0 that used to be left to Octopus would be released or driven. Car 0 goes back to the claim alone; only cars after it, which had no slot at all under the claim before #5443, are judged on their own sensor - and one whose sensor has lost its value is "cannot tell" rather than handed to Octopus. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…e survives a restart Review changes from Trefor on #5448. ge_cloud_evc_control and myenergi_zappi_control default to false again, so an upgrade never starts Predbat driving a charger nobody asked it to drive. Control runs only with an explicit true, and still stands down where Octopus Intelligent drives the charger or the car. MyEnergiAPI.automatic_set_by_user() is removed. The mode a Zappi had before Predbat took over is now saved to storage and restored on startup, so a restart no longer snapshots Predbat's own Stopped as the mode to release to. With that fixed, a saved Stopped is restored like any other mode, on release and on the hand-over to Octopus (which still never uses Fast). Modes left in storage are dropped when control is off at startup. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.



Posted by Claude on behalf of @chalfontchubby.
Folds the former stack #5284 (shared charger-control mixin) and #5311 (control on automatically, Octopus Intelligent, guest charging) into one PR for a single final review, as Trefor suggested on #5284. It supersedes both, which will be closed once this is open. All their review threads were already answered and resolved; their commit history is kept as it was, so earlier review comments still map to commits.
Rebased onto main (8 Oct). One commit dropped: the gateway commit that moved its car plan parsing onto the shared parser, which main now has from #5120. Ohme's New Year tests from #5120 are ported to the shared control API. A local
/code-review highbefore pushing found two small bugs in the existing code, fixed in the last commit: a dispatch time with no UTC offset raised a TypeError when compared with the clock (now read as UTC), and anis_chargerof unknown/unavailable was read as "not the charger" instead of "cannot tell".A later local review fixed one more (9c59c22): the Octopus/Kraken discovery wait is now timed per car, so a car whose driver is known no longer restarts another car's 15-minute wait. Before, in a multi-car setup, a wired car reset the shared timer every cycle, so a car still waiting on discovery never reached "cannot tell" and its charger was held as it was indefinitely.
Known and not changed here (from the same review): the Ohme charger is keyed by serial or the literal "ohme", which would orphan held state if the serial arrives late; the guest switch republishes on the next poll rather than immediately.
Update, 12 Oct: control stays opt-in (91f9f97)
Review changes from Trefor, pushed to this branch. Where the text below disagrees with this section, this section is current.
ge_cloud_evc_controlandmyenergi_zappi_controldefault tofalseagain, as on main, so nobody's charger behaves differently on upgrade unless they had already set its control setting totrue.ohme_controlwas already opt-in.MyEnergiAPI.automatic_set_by_user()is removed.myenergi/control_saved_modes) and loaded on the first run. A restart used to lose it, and the next snapshot was Predbat's own Stopped. Modes left in storage are dropped if control is off at startup.car_charger_control,ge_cloud,myenergi,ohme,car_charging_smartandcomponentstest groups, and pre-commit on the changed files. The full suite was not run locally for this commit.Two consequences of control only ever running with
true:Part 1: shared mixin (was #5284)
Summary
Predbat-led EV charger control (start/stop the charger from the car charging plan) was implemented three times, once each in
gecloud.py(GivEnergy EV charger),myenergi.py(Zappi) andohme.py, with a fourth window parser ingateway.py. This PR moves the shared loop into one mixin,CarChargerControl(car_charger_control.py), before we add more chargers (Hypervolt, Wallbox).The mixin owns:
binary_sensor.predbat_car_charging_slot[_N]Each component keeps only what is specific to its charger: which chargers exist and in which order, whether a car is connected, how drift is detected, and the on/off/release commands. Log wording for those commands is unchanged.
One commit per step; each passes the quick suite on its own:
Behaviour changes
Intended to be a refactor, with these exceptions:
parse_car_plan_windows(). The gateway copy also moved any window starting more than 23 hours ago a year forward; a finished window now stays finished.num_cars(briefly true while auto-config'snum_carsreaches the base), an extra Zappi is now left alone instead of Stopped, matching what GivEnergy EVC already did. A charger Predbat was already holding when its car drops out ofnum_carsis released back to its own mode rather than left in the state Predbat last set.async_send_evc_command()reports a refusal by returning None, so a refused start, stop or release used to be recorded as sent and never retried; a refused release could strand a stopped charger. GE charger control now raisesEVCCommandFailedon a refusal, so nothing is recorded and the command is tried again next cycle. GE's run loop catches it as a warning, as Ohme's and myenergi's do.base.set_read_onlyis unset, the EVC loop now falls back to theset_read_onlyarg like the other chargers, not the switch entity. Predbat sets the attribute at startup (predbat.py), so this only affects test doubles.GECloudDirect.read_only_now()is kept for the inverter code that uses it.num_carskept its saved mode, so taking it back later restored that stale mode on the next release. The saved mode is now dropped once that Zappi's release goes through.Gateway control is not moved onto the mixin here: that would add release on read only, which is a behaviour change. It belongs in a follow-up.
Testing
tests/test_car_charger_control.pycovers the mixin against a fake component.run(), and a new mixin test covers a release that fails part-way through several chargers. Both come from an adversarial review; the Ohme test fails without the fix.num_carsbeing released, and GE control tests 11 and 12 cover a refused stop and a refused release being retried rather than recorded.tools/debug-journal.md's myenergi entry is updated for the renamed methods.charger_control_state/charger_control_release()), with the same retry until it succeeds, and feat(ohme): take the car plan from Ohme's own schedule when Predbat is not controlling the charger #5401's tests are updated for the new state names.Part 2: Octopus Intelligent rule and guest charging (was #5311)
What this does
Stage 2 of Predbat-led EV charger control. Control stays opt-in for every charger, as on main:
falsetruege_cloud_evc_controlge_cloud_automatic_evc, and warns if it is missingohme_controlohme_automaticmyenergi_zappi_controlmyenergi_automatic,myenergi_automatic_zappiandmyenergi_enable_controls, and warns if one is missingFor chargers under control it adds three things, each described below:
Behaviour change on upgrade
Users who have not set a control setting to
truesee no change to their charger.Users who already had
*_control: trueget the new Octopus rule and the guest switch. Two parts of the Octopus rule change things for them:switch.predbat_octopus_intelligent_charger_follows_caris on, where before it drove the charger to its plan.A charger Predbat drives is also switched on while a dispatch on the car's dispatch sensor is running, as well as inside its plan.
For homes with more than one car, each car's
binary_sensor.predbat_car_charging_slot_Nnow carries only that car's windows (7fac8d5), which also changes what the Wallbox component and any user automation read from it.The docs cover this in
car-charging.md, in the section "Predbat starting and stopping your charger". The Octopus rule probably wants a line in the release notes.Decisions, and the options rejected
ge_cloud_automatic_evc, and Zappi control on when the user had writtenmyenergi_automaticormyenergi_automatic_zappiinto apps.yaml. Both are withdrawn in review: an upgrade should not start Predbat driving a charger, and a Zappi Predbat controls is Stopped between windows, so it stops diverting solar in Eco/Eco+.is_chargerfrom the car's own dispatch sensor inoctopus_intelligent_slot. Both the Octopus and Kraken components publish it, so E.ON/EDF SmartFlex is covered, and a car can't be paired with another car's device. What Predbat does depends on which device Octopus drives:switch.predbat_octopus_intelligent_chargingsays. That switch only changes Predbat's own planning; Octopus keeps switching the charger either way, so driving it would fight Octopus.switch.predbat_octopus_intelligent_charger_follows_car(default off), has Predbat drive the charger instead: on during dispatches and off otherwise, so the car cannot charge on its own timers. It follows the plan and also the dispatch times on the sensor, judged against the clock, so it picks up a new dispatch without waiting for the 5-minute plan and stops the charger when the dispatch ends. Withoctopus_intelligent_chargingoff, Predbat plans the car itself and the charger follows that plan, whatever the new switch says. The Ohme follows the same rules (bbbfb3f), so with the switch onohme_control: truecan run where fix(ohme): leave the Intelligent car slots to Octopus when the Intelligent device is the car #5405 would otherwise stand it down.*_control: true, which is the user saying their charger is not the Octopus device. The mixin can instead leave such a charger alone, with a warning and a 15-minute wait for discovery (6cec384), but only for a component that passes its control setting as unset, and none does now.switch.predbat_gecloud_guest_charging,switch.predbat_myenergi_guest_chargingandswitch.predbat_ohme_guest_charging.Fixes found in review before opening
octopus_automaticoff, Predbat waited for Octopus discovery that never came, so control never turned on."false"or a0read as on, because removing the defaults also skippedget_arg()'s boolean conversion.parse_control_setting()now normalises them.Found by a further
/code-reviewafter opening:Merged with main (12 Oct)
Main is merged in (ace254e), not rebased, as the PR is under review. It brought #5443, under which Octopus provides an Ohme's completed Intelligent dispatches and the Ohme provides the planned ones. The one conflict, in
OhmeAPI.__init__, is between independent state: #5443'sslot_sourceand this PR'sfollows_car. Both are kept, and the rest ofupdate_slot_mode()merged cleanly with both sides intact.Two follow-ups from that merge:
control_active, which this PR renamed tocharger_control_active. Only the name changes.octopus_intelligent_slotwhile the Ohme holdscar_slot_owner, so cars after the first now have a sensor where before they had none. This PR treated the claim as "Octopus drives the charger" for every car, which would hand a Zappi or GE charger on car 1 to Octopus even when Octopus drives that car itself. The claim now decides car 0 only, unchanged from before. Each later car is judged on its own sensor'sis_charger. A new test covers it and fails without the fix.Known and not changed: when an Ohme shares a home with a second charger, which car each charger follows still depends on the order of Octopus's device ids. The claim always covers car 0, and the Ohme's own dispatch sensor may sort to index 1. The same ordering affects #5443's choice of sensor on main.
Rebased onto main (5 Oct)
The stack is rebased onto main, which meanwhile changed the Ohme component in #5401 and #5405. How the two fit:
enable_control()is re-decided whenever the tariff or Intelligent device changes (fix(ohme): leave the Intelligent car slots to Octopus when the Intelligent device is the car #5405), and also when the follows-car or Intelligent charging switch changes while Octopus drives the car.ohme_controlleft off, Ohme's own schedule stays the car plan.Found by review after the rebase:
re:string, before its regex matches, was read as a dispatch sensor (5394c56).Found in review on this PR (11 Oct)
plannedattribute was driven from an empty plan and stopped mid-window. The windows are absolute times, so the last ones read are kept.publish_car_plan()inoutput.pybuilt one plan list and handed the same list to every car's sensor, so with two or more cars each sensor'splannedheld all of them. This is on main too, but this PR drives charger N from car N'splanned, so a charger would start in another car's window. The fix is one line: the list is created per car.control_active, notcharger_control_active.Each behaviour fix has a test that fails without it. These commits were checked at the tip with the quick suite and pre-commit, not one by one.
Not in this PR (known and deferred)
ohme_automatic_octopus_intelligent: has the same quoted-"false"problem, from before this PR.num_carsat 0 there is no plan to read, so control does nothing that cycle, including releasing a charger it holds. This comes from refactor(car): share Predbat-led EV charger control across Ohme, Zappi and GivEnergy #5284 and is unchanged.true: an explicittrueskips the wait for Octopus or Kraken discovery, so for a cycle or two after a restart a charger Octopus drives can be commanded before its dispatch sensor is wired. This was already the case fortrueusers; it now applies to everyone under control.Testing
test_car_charger_control.py,test_ge_cloud.py,test_ohme.pyandtest_myenergi.py./code-review high. Their findings are the fixes listed above.🤖 Generated with Claude Code