SolisCloud: Clear time windows for charge/discharge to prevent overlapping windows #3786

Description

@CraigCallender

Describe the bug
When Predbat controls a Solis inverter via the SolisCloud API in TOU V2 mode, writing a new charge or discharge time window can fail if another slot still has stale (non-zero) times on the inverter from a previous cycle where the clear write failed. The SolisCloud API rejects writes that would create overlapping time windows across slots, even if the conflicting slot is disabled.

Expected behaviour
When a charge or discharge slot is disabled, its start and end times should be cleared to 00:00-00:00 on the inverter. This should happen before the active slot's new window is written, so there is no risk of an overlap rejection from the API.

Predbat version
8.36.3

Environment details

  • Solis inverter with SolisCloud API integration (TOU V2 mode, i.e. CID 6798 enabled)
  • Multiple charge/discharge slots previously set by Predbat or manually, leaving non-zero times in slots 2–6
  • Standard HAOS installer or Docker
  • Only affects inverter_type: SolisCloud configurations using the V2 register layout

Activity

  1. CraigCallender commented on Apr 14, 2026

    @CraigCallender
    ContributorAuthor

    PR in #3787

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment