Expand Up @@ -2881,7 +2881,7 @@
- pipe.calculation_point_distance should preferably be at least 5.0 metres to prevent simulation timestep reduction.
* - 0045
- Future_error
- connection_node.storage_area should be defined and greater than 0 if the connection nodes has no connections to channels, culverts, pipes, weirs, or orifices0. From September 2025 onwards, this will be an ERROR.
- connection_node.storage_area should be defined and greater than 0 if the connection node has no connections to channels, culverts, pipes, weirs, or orifices. From September 2025 onwards, this will be an ERROR.
* - 0046
- Future_error
- A connection node that is not connected to a pipe, channel, culvert, weir, or orifice must have a defined bottom_level.
Expand Down Expand Up @@ -2960,6 +2960,9 @@
* - 0074
- Error
- boundary_condition_1d cannot have a groundwater type
* - 0075
- Warning
- 2D boundary condition overlaps with grid refinement area. Make sure it is either completely contained by (within) or disjoint from the grid refinement polygon.
* - 0080
- Error
- Either cross_section_location.friction_value or cross_section_location.cross_section_friction_values must be defined for a CrossSectionShape.TABULATED_YZ cross section shape
Expand Down Expand Up @@ -3160,10 +3163,10 @@
- pump.lower_stop_level should be higher than connection_node.bottom_level. In the future, this will lead to an error.
* - 0106
- Warning
- connection_node.exchange_level >= connection_node.bottom_level when connection_node.exchange_type is CONNECTED. In the future, this will lead to an error.
- connection_node.exchange_level must be >= connection_node.bottom_level when connection_node.exchange_type is CONNECTED. In the future, this will lead to an error.
* - 0107
- Warning
- connection_node.exchange_level cannot be null when using sub-basins (model_settings.manhole_aboveground_storage_area > 0) and no DEM is supplied.
- Error
- connection_node.exchange_level cannot be null when using sub-basins (model_settings.manhole_aboveground_storage_area > 0) and/or a DEM is supplied.
* - 0108
- Warning
- orifice.crest_level should be higher than or equal to connection_node.bottom_level for all the connected manholes.
Expand Down Expand Up @@ -3373,7 +3376,7 @@
- This connection node is not connected to a pipe, channel, culvert, weir, orifice or pumpstation.
* - 0252
- Warning
- When connecting two isolated pipes, it is recommended to add storage to the connection node.
- When connecting two isolated or connected pipes, it is recommended to add storage to the connection node.
* - 0253
- Future_error
- a channel cannot be connected to itself (connection_node_id_start must not equal connection_node_id_end)
Expand Down Expand Up @@ -3451,7 +3454,7 @@
- model_settings.calculation_point_distance_1d is not greater than 0, in the future this will lead to an error
* - 0307
- Error
- model_settings.minimum_cell_size is <=0
- model_settings.minimum_cell_size is <=0; this is not allowed when model_settings.dem_file is filled in
* - 0308
- Error
- model_settings.embedded_cutoff_threshold is <0
Expand All @@ -3469,7 +3472,7 @@
- model_settings.friction_coefficient is <0 and/or >1
* - 0314
- Error
- model_settings.friction_coefficient is <0
- model_settings.friction_coefficient is <1
* - 0315
- Error
- interception.interception is <0
Expand Down Expand Up @@ -3778,10 +3781,10 @@
- connection_node.id has more than 50 surface areas mapped to it; this might be an error.
* - 0616
- Warning
- No inflow will be generated for this feature, because model_settings.use_0d_inflow is not set to use dry_weather_flow.
- No dry weather inflow will be generated for this feature, because simulation_template_settings.use_0d_inflow is set to False.
* - 0616
- Warning
- No inflow will be generated for this feature, because model_settings.use_0d_inflow is not set to use surface.
- No surface inflow will be generated for this feature, because simulation_template_settings.use_0d_inflow is set to False.
* - 0617
- Warning
- model_settings.use_0d_inflow is set to use dry_weather_flow, but dry_weather_flow does not contain any features.
Expand All @@ -3806,6 +3809,12 @@
* - 0623
- Error
- The values in dry_weather_flow_distribution.dry_weather_flow_distribution.distribution should add up to 100 %
* - 0624
- Warning
- Dry weather flow does not have dry weather flow map. It will be ignored. Make sure that this is intentional.
* - 0624
- Warning
- Surface does not have surface map. It will be ignored. Make sure that this is intentional.
* - 0700
- Warning
- raster checks require GDAL to be available
Expand Down Expand Up @@ -4096,7 +4105,7 @@
- numerical_settings.cfl_strictness_factor_2d is <=0
* - 1112
- Error
- numerical_settings.convergence_eps is <1e-07 and/or >0.0001
- numerical_settings.convergence_eps is <1e-11 and/or >0.0001
* - 1113
- Error
- numerical_settings.convergence_cg is <1e-12 and/or >1e-07