UPS Status

An Omarchy bar widget for a UPS monitored by apcupsd: battery charge on the bar, the details in a panel, and the machines the UPS powers, with a notification when mains power is lost or restored.

The UPS Status panel: model, mains power and charge with a charge bar, runtime, load in percent and watts, status, battery date, transfers, the server, and the machines on the UPS with a green dot for each one that answers

Bar shows Meaning
󰚥 100% On mains power, battery charge
󰂄 90% On mains, battery recharging (below 95%)
󰂃 80% 45m (highlighted) On battery: charge and minutes left
󰚦 UPS? (highlighted) apcupsd isn't answering
  • Hover: a one-line summary and how many of your machines answer.
  • Click: the panel. It shows model, mains voltage, a charge bar, runtime, load (% and watts), status, battery date, number of transfers and the reason for the last one, the apcupsd server, and the machines on the UPS. A filled dot means the machine answers a ping and a hollow one means it doesn't. The line for this machine also shows its own apcupsd client status. R or Refresh checks now, Esc closes it. Right-click checks now and opens the panel.
  • Notifications, only on a change: on battery is critical (stays on screen until dismissed); not answering and the matching power restored / answering again are normal and close by themselves, since a silent UPS server is almost always the network, not the power. "Not answering" takes 8 failed checks in a row (about 2 minutes at the default interval), so a brief network blip or a busy apcupsd doesn't raise an alarm. "notify": false turns them all off.

It works with any UPS apcupsd supports (APC, and CyberPower and others through the USB HID driver), whether the UPS is plugged into this machine or into another one on your network.

Install

omarchy plugin add https://github.com/jchisholm59/omarchy-ups-status.git --enable

Needs apcaccess, which comes with the apcupsd package (install it with your package manager), and python3, ping and notify-send, all part of a stock Omarchy install. The plugin itself runs without elevated privileges.

With no settings it reads your own apcupsd at 127.0.0.1:3551. That works when the UPS is plugged into this machine, and when this machine is an apcupsd network client (UPSCABLE ether, UPSTYPE net, DEVICE <server>:3551) of the machine that has the UPS. Either way, apcupsd's Network Information Server has to be on (NETSERVER on, the default).

Settings

Add any of these to the widget's entry in ~/.config/omarchy/shell.json. The bar reloads on save.

{
  "id": "jim.ups-status",
  "server": "192.168.1.45:3551",
  "machines": [
    { "name": "nas", "host": "192.168.1.20" },
    { "name": "dns", "host": "192.168.1.33" },
    "router=192.168.1.1"
  ],
  "interval": 15,
  "notify": true
}
Setting Default
server 127.0.0.1:3551 Any apcupsd Network Information Server (host:port; the port defaults to 3551). Point it at the machine the UPS is plugged into to read it directly. That machine's apcupsd must listen on the network (NISIP 0.0.0.0).
machines none The machines on the UPS, as { "name", "host" }, "name=host" or just "host". Each gets one ping per check. Leave it out to hide the list.
interval 15 Seconds between checks (minimum 5).
notify true Set to false to turn the notifications off.

allowMultiple is on, so you can add a second entry with a different id suffix and server to watch another UPS.

How it works

Every interval seconds, bin/ups-status runs apcaccess status <server> and pings each machine once (1 s timeout, all in parallel), then prints one JSON object for the panel. It reads only what apcupsd reports, and it never sends commands to the UPS or changes apcupsd's configuration. Nothing leaves your network.

Remove

omarchy plugin remove jim.ups-status

That turns the widget off and deletes the plugin folder. It keeps no files of its own anywhere else, and apcupsd itself is left as it was.