1 change: 1 addition & 0 deletions CHANGELOG.rst
Original file line number Diff line number Diff line change
Expand Up @@ -10,6 +10,7 @@ Change Log
- [CHANGED] ideal phase shifters only use ``tap_step_degree`` as angle per tap step. ``tap_step_percent`` must be NaN or 0
- [REMOVED] ``tap_phase_shifter`` / ``tap2_phase_shifter``: phase shifters are only defined by ``tap_changer_type`` / ``tap2_changer_type``
- [ADDED] added a sensitivity package, it provides LODF, PSDF and PTDF calculation based on the DC power flow
- [ADDED] TDPF: top-oil and hot-spot temperatures of ``net.trafo`` and ``net.trafo3w``, based on IEC 60076-7 and the optional ``transformer-thermal-model`` package (``pip install pandapower[tdpf]``); the thermal model runs as post-processing on the solved loading, so ``r_sc`` is unchanged and voltages/flows do not change; new input columns ``cooling_type`` (ONAN/ONAF, default ONAN) and ``air_temperature_degree_celsius`` (default 35) and new result columns ``top_oil_temperature_degree_celsius``, ``hot_spot_temperature_degree_celsius`` (2W) / ``hot_spot_temperature_degree_celsius_hv|mv|lv`` (3W) and ``temperature_degree_celsius``; without the package a warning is logged and line TDPF is unaffected
- [FIXED] ``res_dcline``: a terminal at an unsupplied bus (island without slack) now has ``NaN`` as voltage magnitude and angle, consistent with ``res_bus``, instead of ``0``
- [FIXED] branch voltage angle difference constraints (MATPOWER ``ANGMIN``/``ANGMAX``) were lost in the pypower/matpower converters and ignored by the OPF: the new optional columns ``min_angle_degree`` and ``max_angle_degree`` in ``net.line``, ``net.trafo``, ``net.trafo3w`` and ``net.impedance`` are considered by ``runopp``/``rundcopp`` and by ``to_pm``, and ``from_ppc``/``to_ppc``/``to_mpc`` preserve them (#2385). For ``net.trafo3w`` the limit bounds each internal star branch (hv -> star and star -> mv/lv) separately, so the terminal difference can reach twice the configured value. OPF results of networks imported from MATPOWER/PYPOWER cases with angle limits change accordingly; pass ``OPF_IGNORE_ANG_LIM=True`` to ``runopp`` to ignore the limits.
- [FIXED] matpower/pypower converter: transformers without a tap changer (tap ratio 1) were converted to impedance elements by a to_mpc/from_mpc (and to_ppc/from_ppc) round trip, since a tap ratio of 1 was not recognized as a transformer when importing. The converters now follow the matpower convention (a tap ratio of 0 denotes "no transformer", any other ratio denotes a transformer): ``to_mpc`` keeps the tap ratio of transformer branches, ``from_mpc`` no longer rewrites tap ratios of 0, ``to_ppc`` marks branches of impedance elements with a tap ratio of 0, and ``from_ppc`` only imports branches without a tap ratio and without a phase shift that connect different voltage levels as impedances. The tap ratio marking also stays correct when branches are filtered out of the internal ppc (out-of-service or disconnected branches). A transformer with a tap ratio of 1 between buses of the same voltage level still cannot be distinguished from a line in the ppc/matpower format and keeps being converted to a line on the way back, as before (#2620)
Expand Down
1 change: 0 additions & 1 deletion doc/about/license.rst
Original file line number Diff line number Diff line change
Expand Up @@ -10,4 +10,3 @@ License
pandapower is published under the following 3-clause BSD license:

.. literalinclude:: ../../LICENSE

9 changes: 9 additions & 0 deletions doc/elements/trafo.rst
Comment thread
vogt31337 marked this conversation as resolved.
Resolved
Original file line number Diff line number Diff line change
Expand Up @@ -35,6 +35,11 @@ Table Structure

.. note:: The transformer loading constraint for the optimal power flow corresponds to the option trafo_loading="current":

.. note:: The columns ``cooling_type`` and ``air_temperature_degree_celsius`` are only used by the
transformer thermal calculation of the temperature dependent power flow, see
:ref:`Transformer temperatures <tdpf_transformer_temperatures>`. They default to ``"ONAN"`` (Oil Natural, Air Natural) and
``35`` °C, so they can be left empty.

.. note:: vkr_percent can be calculated as follow :

.. math::
Expand Down Expand Up @@ -404,6 +409,10 @@ Result Tables
:header-rows: 1
:delim: ,

.. note:: With ``runpp(tdpf=True)`` the columns ``top_oil_temperature_degree_celsius``,
``hot_spot_temperature_degree_celsius`` and ``temperature_degree_celsius`` are added, see
:ref:`Transformer temperatures <tdpf_transformer_temperatures>`.

.. math::
:nowrap:

Expand Down
10 changes: 10 additions & 0 deletions doc/elements/trafo3w.rst
Original file line number Diff line number Diff line change
Expand Up @@ -44,6 +44,11 @@ Table Structure

.. note:: Three Winding Transformer loading can not yet be constrained with the optimal power flow.

.. note:: The columns ``cooling_type`` and ``air_temperature_degree_celsius`` are only used by the
transformer thermal calculation of the temperature dependent power flow, see
:ref:`Transformer temperatures <tdpf_transformer_temperatures>`. They default to ``"ONAN"`` (Oil Natural, Air Natural) and
``35`` °C, so they can be left empty.

.. _trafo3w_model:

Electric Model
Expand Down Expand Up @@ -173,6 +178,11 @@ Result Tables
:header-rows: 1
:delim: ,

.. note:: With ``runpp(tdpf=True)`` the columns ``top_oil_temperature_degree_celsius``,
``hot_spot_temperature_degree_celsius_hv``, ``hot_spot_temperature_degree_celsius_mv``,
``hot_spot_temperature_degree_celsius_lv`` and ``temperature_degree_celsius`` are added, see
:ref:`Transformer temperatures <tdpf_transformer_temperatures>`.

.. math::
p\_hv\_mw &= Re(\underline{v}_{hv} \cdot \underline{i}_{hv}) \\
q\_hv\_mvar &= Im(\underline{v}_{hv} \cdot \underline{i}_{hv}) \\
Expand Down
82 changes: 82 additions & 0 deletions doc/powerflow/ac.rst
Original file line number Diff line number Diff line change
Expand Up @@ -127,6 +127,88 @@ More detailed information about TDPF can be found in the tutorials:

- `TDPF introduction <https://github.com/e2nIEE/pandapower/blob/develop/tutorials/temperature_dependent_power_flow.ipynb>`__
- `Sensitivity of TDPF parameters <https://github.com/e2nIEE/pandapower/blob/develop/tutorials/temperature_dependent_power_flow_parameters.ipynb>`__
- `Transformer temperatures <https://github.com/e2nIEE/pandapower/blob/develop/tutorials/temperature_dependent_power_flow_trafo.ipynb>`__

.. _tdpf_transformer_temperatures:

Transformer temperatures
````````````````````````

In addition to the conductor temperature of the lines, TDPF reports the top-oil and hot-spot temperature
of every in-service transformer (:code:`net.trafo` and :code:`net.trafo3w`). The calculation is based on
the IEC 60076-7 loading guide and utilizes the python package
`transformer-thermal-model <https://github.com/alliander-opensource/transformer-thermal-model>`__ developed by Alliander.

This is an optional feature and requires an optional dependency. Install it with:

.. code-block:: bash

pip install pandapower[tdpf]

If the package is not installed, TDPF logs a warning and skips transformer temperature calculations.
Line TDPF continues to work as before. Transformer temperature result columns are not created,
so line-only TDPF users do not see columns filled with NaN values.

Two additional input columns are read from :code:`net.trafo` and :code:`net.trafo3w`:

.. tabularcolumns:: |p{0.30\linewidth}|p{0.15\linewidth}|p{0.45\linewidth}|
.. csv-table::
:header: "Column", "Type", "Description"
:widths: 30, 15, 45

``cooling_type``,string,"cooling type of the transformer, either ONAN or ONAF (default: ONAN)"
``air_temperature_degree_celsius``,float,"ambient air temperature in °C (default: 35)"

The temperature is *reported*, not fed back into the power flow. In contrast to the line TDPF, the
transformer resistance :code:`r_sc` is never modified, because the thermal model runs as post-processing
on the solved transformer loading. The results are therefore not iterated with the power flow and do not
change voltages, flows or losses.

The results are written to additional columns of :code:`net.res_trafo` and :code:`net.res_trafo3w`:

.. tabularcolumns:: |p{0.35\linewidth}|p{0.30\linewidth}|p{0.35\linewidth}|
.. csv-table::
:header: "Column", "Table", "Description"
:widths: 35, 30, 35

``top_oil_temperature_degree_celsius``,"res_trafo, res_trafo3w","top-oil temperature in °C"
``hot_spot_temperature_degree_celsius``,"res_trafo","hot-spot temperature in °C"
``hot_spot_temperature_degree_celsius_hv``,"res_trafo3w","hot-spot temperature of the HV winding in °C"
``hot_spot_temperature_degree_celsius_mv``,"res_trafo3w","hot-spot temperature of the MV winding in °C"
``hot_spot_temperature_degree_celsius_lv``,"res_trafo3w","hot-spot temperature of the LV winding in °C"
``temperature_degree_celsius``,"res_trafo, res_trafo3w","hottest hot-spot temperature in °C, used by the contingency limit checks"

For a three winding transformer, :code:`temperature_degree_celsius` is the maximum of the three winding
hot-spot temperatures, mirroring how :code:`loading_percent` aggregates the windings.

Whether the model is solved for the steady state or for a transient depends on the :code:`tdpf_delay_s`
power flow parameter, the same parameter that controls the thermal inertia of the lines:

* :code:`tdpf_delay_s=None` (the default) gives the steady state temperature for the current loading.
* A finite :code:`tdpf_delay_s` gives the temperature after this time step, starting from a cold
transformer. In a time series run (:code:`pandapower.timeseries.run_timeseries`), the top-oil temperature
of the previous time step is used as the initial condition, so the transformer warms up and cools down
continuously over the simulation.

.. note::

The ONAN and ONAF cooling types share the same steady state temperature. They only differ in the
transient behaviour: an ONAF transformer has shorter oil and winding time constants and therefore
reaches its final temperature faster, not at a lower temperature.

.. note::

Only the nameplate data that pandapower already stores is passed to the thermal model: the no-load
loss, the load loss, the rated apparent power and the rated voltages of each winding, which yield
the nominal currents. The optional specifications of the loading guide -- above all
:code:`winding_oil_gradient`, :code:`hot_spot_fac` and the winding and oil time constants -- are
left at the IEC 60076-7 defaults of the library (17 K, 1.3 and the values for the selected cooling
type).

The top-oil temperature depends only on the nameplate data and therefore matches a calculation with
modified optional specifications exactly. The hot-spot temperature does depend on them, so it will
differ from a calculation that uses a transformer-specific winding-oil gradient or hot-spot factor.
A wider set of input columns is not part of this implementation.

.. autofunction:: pandapower.run.runpp

Expand Down
3 changes: 3 additions & 0 deletions mypy.ini
Original file line number Diff line number Diff line change
Expand Up @@ -64,5 +64,8 @@ ignore_missing_imports = true
[mypy-pypower.*]
ignore_missing_imports = true

[mypy-transformer_thermal_model.*]
ignore_missing_imports = true

[mypy-xlsxwriter.*]
ignore_missing_imports = true
73 changes: 58 additions & 15 deletions pandapower/auxiliary.py
Original file line number Diff line number Diff line change
Expand Up @@ -1500,6 +1500,10 @@
if len(tdpf_lines) == 0:
logger.info("TDPF: no relevant lines found")

# transformers are always included in the thermal calculation when tdpf=True (no opt-in flag)
trafo_idx = net.trafo.index[net.trafo.in_service.values] if len(net.trafo) else net.trafo.index[:0]
trafo3w_idx = net.trafo3w.index[net.trafo3w.in_service.values] if len(net.trafo3w) else net.trafo3w.index[:0]

# required for simplified approach if r_theta_kelvin_per_mw is provided, can be filled with simplified values:
default_values = {
"temperature_degree_celsius": 20, # starting temperature of lines
Expand Down Expand Up @@ -1533,20 +1537,22 @@
# if np.any(np.setdiff1d(net.line.columns, required_columns)):
# raise UserWarning(f"TDPF: required columns missing in net.line: {required_columns}")

missing_columns = []
for col in required_columns:
if col not in net.line.columns or np.any(net.line.loc[tdpf_lines, col].isnull()):
missing_columns.append(col)

if len(missing_columns) > 0:
raise UserWarning(f"TDPF: required columns {missing_columns} are missing or have missing values")

# check if unsupported elements are included
if (
len(net.line.loc[net.line.index.isin(tdpf_lines) & (net.line.type == "cs")]) > 0
or "tdpf" in net.trafo
or "tdpf" in net.trafo3w
):
# The line columns are only validated if the network contains lines at all. A network with only
# transformers (no lines) still gets transformer temperatures, so there is nothing to check here.
if len(net.line) > 0:
missing_columns = []
for col in required_columns:
# `tdpf` selects the lines and therefore has to exist for the branch conversion, but only
# the values of the selected lines are relevant. An ordinary line that did not opt in must
# not trigger a missing-value warning for a column it never needed.
if col not in net.line.columns or (len(tdpf_lines) > 0 and np.any(net.line.loc[tdpf_lines, col].isnull())):
missing_columns.append(col)

if len(missing_columns) > 0:
raise UserWarning(f"TDPF: required columns {missing_columns} are missing or have missing values")

# check if unsupported elements are included; the "type" column is optional in the line schema
if len(tdpf_lines) > 0 and "type" in net.line.columns and (net.line.loc[tdpf_lines, "type"].dropna() == "cs").any():
logger.warning("TDPF: temperature dependent power flow is only implemented for overhead lines")

# now fill in the default values
Expand All @@ -1557,9 +1563,46 @@
logger.info(f"TDPF: filling nan values in {col} with a default assumption of {val}")
net.line.loc[tdpf_lines, col] = net.line.loc[tdpf_lines, col].fillna(val)

if len(net.line.loc[net.line.index.isin(tdpf_lines) & (net.line.r_ohm_per_km == 0)]) > 0:
if len(net.line) > 0 and len(net.line.loc[net.line.index.isin(tdpf_lines) & (net.line.r_ohm_per_km == 0)]) > 0:
raise UserWarning("TDPF: temperature dependent power flow cannot be applied to lines that have r_ohm_per_km=0")

_check_tdpf_trafo_parameters(net, trafo_idx, trafo3w_idx)


def _check_tdpf_trafo_parameters(net: pandapowerNet, trafo_idx, trafo3w_idx) -> None:

Check failure on line 1572 in pandapower/auxiliary.py

View check run for this annotation

SonarQubeCloud / SonarCloud Code Analysis

Refactor this function to reduce its Cognitive Complexity from 16 to the 15 allowed.

See more on https://sonarcloud.io/project/issues?id=e2nIEE_pandapower&issues=AaHK3CDhOjZ0WOONG-mK&open=AaHK3CDhOjZ0WOONG-mK&pullRequest=3325
"""Default and validate the transformer input columns of the transformer thermal calculation.

Every in-service transformer takes part in the thermal calculation when ``tdpf=True``; there is no
per transformer opt-in flag. Only ``cooling_type`` and ``air_temperature_degree_celsius`` are
required inputs, everything else is derived from the nameplate data.
"""
trafo_defaults = {"cooling_type": "ONAN", "air_temperature_degree_celsius": 35}
for element, indices in (("trafo", trafo_idx), ("trafo3w", trafo3w_idx)):
if len(indices) == 0:
continue
table = net[element]
if "cooling_type" not in table.columns:
table["cooling_type"] = pd.Series(pd.NA, index=table.index, dtype="string")
if "air_temperature_degree_celsius" not in table.columns:
table["air_temperature_degree_celsius"] = np.nan
for col, val in trafo_defaults.items():
if np.any(pd.isnull(table.loc[indices, col])):
logger.info(f"TDPF: filling nan values in {element}.{col} with a default assumption of {val}")
# normalise the cooling type, so that the library mapping is unambiguous
table["cooling_type"] = table["cooling_type"].astype("string")
table.loc[indices, "cooling_type"] = table.loc[indices, "cooling_type"].str.strip().str.upper().fillna("ONAN")
table.loc[indices, "air_temperature_degree_celsius"] = (
table.loc[indices, "air_temperature_degree_celsius"].astype(float).fillna(35.0)
)
invalid = ~table.loc[indices, "cooling_type"].isin(["ONAN", "ONAF"])
if invalid.any():
raise UserWarning(
f"TDPF: invalid cooling_type in {element} for indices {table.loc[indices].index[invalid].tolist()}, "
"must be 'ONAN' or 'ONAF'"
)
if (table.loc[indices, "air_temperature_degree_celsius"] <= -273).any():
raise UserWarning(f"TDPF: air_temperature_degree_celsius in {element} must be greater than -273 °C")


# =============================================================================
# Functions for 3 Phase Unbalanced Load Flow
Expand Down
24 changes: 20 additions & 4 deletions pandapower/contingency/contingency.py
Original file line number Diff line number Diff line change
Expand Up @@ -22,6 +22,7 @@

from pandapower.create._utils import add_column_to_df
from pandapower.network import pandapowerNet
from pandapower.pf.transformer_thermal import TRANSFORMER_THERMAL_AVAILABLE
from pandapower.run import runpp

logger = logging.getLogger(__name__)
Expand Down Expand Up @@ -154,12 +155,23 @@ def run_contingency(
"bus": ["vm_pu"],
**{key: ["loading_percent"] for key in ("line", "trafo", "trafo3w") if len(net[key]) > 0},
}
if len(net.line) > 0 and (
tdpf_requested = (
Comment thread
heckstrahler marked this conversation as resolved.
Resolved
net.get("_options", {}).get("tdpf", False)
or pf_options.get("tdpf", False)
or pf_options_nminus1.get("tdpf", False)
):
result_variables["line"].append("temperature_degree_celsius")
)
if tdpf_requested:
if len(net.line) > 0:
result_variables["line"].append("temperature_degree_celsius")

# transformer temperatures are post-processing results of the transformer thermal model. They
# are produced by every solve once tdpf is on, no matter whether the input network already
# carries the result column -- a fresh network does not, so the column cannot be used to
# decide this before the first solve.
if TRANSFORMER_THERMAL_AVAILABLE:
for element in ("trafo", "trafo3w"):
if len(net[element]) > 0:
result_variables[element].append("temperature_degree_celsius")

# for n-1
for element, val in nminus1_cases.items():
Expand Down Expand Up @@ -414,7 +426,11 @@ def _update_contingency_results(
):
for element, vars in result_variables.items():
for var in vars:
val = net[f"res_{element}"][var].values
res_table = net[f"res_{element}"]
if var not in res_table.columns:
# e.g. the transformer temperature when no transformer took part in this solve
continue
Comment thread
heckstrahler marked this conversation as resolved.
Resolved
val = res_table[var].values
if nminus1:
if var == "loading_percent":
s = (
Expand Down