Uponor Smatrix Pulse X-265 or X-245 with R-208 heating/cooling integration for Home Assistant.
Forked and extended from dave-code-ruiz/uponorX265, which was forked from the original (now unmaintained) asev/homeassistant-uponor.
This integration communicates with the Uponor Smatrix Pulse R-208 communication module. It has been tested with the X-265 and X-245 controllers. Up to 4 controllers with 12 thermostats each are supported.
-
Configure your system in the Uponor Smatrix mobile app and verify that temperature control works. Make sure the R-208 module is connected to your local network and note its IP address.
-
Install via HACS as a custom repository, or copy the
custom_components/uponorx265folder to your Home Assistant/config/custom_components/folder. -
Restart Home Assistant.
-
Go to Settings → Devices & Services → Add Integration → UponorX265 and complete the setup wizard.
If the model of your thermostat/controller does not match or is missing, please run uponorx265.dump_hardware_info and upload the output in a support ticket.
Don't forget to include information about which thermostat/controller model you have.
The setup wizard has four steps:
- Connection — enter the IP address and a name for this gateway.
- Controllers — optionally rename each detected controller. A checkbox lets you choose whether controller devices and sensors should be created in HA.
- Sensors — choose which optional sensors and features to create:
- Current temperature sensor (on by default)
- Valve binary sensor (off by default)
- Average inclusion switch (off by default) — per-thermostat toggle for controller average temperature
- Controller relay/IO sensors (off by default) — pump relay status per controller
- Installer mode (off by default) — see below
- Rooms — optionally rename each detected thermostat/room.
All settings can be changed later via Settings → Devices & Services → UponorX265 → Configure.
Multiple R-208 gateways can be added as separate integration instances. Each instance is fully independent with its own devices, entities, and cached data.
Enabling Installer mode in setup unlocks writable entities for advanced system configuration. When disabled, these settings are visible as read-only sensors instead.
| Setting | Installer mode off | Installer mode on |
|---|---|---|
| Controller relays | Read-only sensor | Writable select |
| Pump control | Read-only sensor (C1 only) | Writable select (C1 only) |
| Bypass (per room) | Read-only binary sensor | Writable switch (max 2 active per controller) |
One climate entity per thermostat.
| Feature | Description |
|---|---|
| Current temperature | Room temperature from the thermostat sensor |
| Target temperature | Read-only when preset is not HA controlled (set by the physical dial) |
| HVAC mode | Heat / Cool / Off |
| Presets | See below |
Presets:
| Preset | Description |
|---|---|
| Comfort | Normal operation — temperature controlled by the physical thermostat dial |
| ECO | Activated by the thermostat's scheduled ECO profile or Temporary ECO in the mobile app |
| Away | Activated by the Away switch (forces ECO mode on all thermostats) |
| HA controlled | Unlocks target temperature control from Home Assistant |
When the preset is anything other than HA controlled, the target temperature is read-only. Attempting to change it shows a notification explaining that the dial is in control and the displayed temperature is immediately refreshed from the controller.
Switching away from HA controlled immediately re-polls the controller so HA shows the temperature the physical dial is set to.
Turn off: since the Uponor API has no true off command, turning off a climate entity sets the setpoint to the minimum (heating mode) or maximum (cooling mode) configured limit.
| Entity | Device | Description |
|---|---|---|
| Away | Gateway | Activates away/ECO mode for all thermostats |
| Automatic firmware update | Gateway | Enables automatic firmware updates on the R-208 module |
| Cooling mode | Gateway | Switches the entire system between heating and cooling mode (only shown if cooling is available) |
| HA controlled (per room) | Thermostat | Per-thermostat toggle for HA temperature control (mirrors the HA controlled preset) |
| Included in average (per room) | Thermostat | Toggles whether the thermostat contributes to the controller's average room temperature (enabled in setup, default: off) |
| Bypass (per room) | Controller | Enables bypass for a room — max 2 active per controller (installer mode only) |
| Entity | Device | Description |
|---|---|---|
| Controller relays | Controller | Relay configuration — Not in use / Pump+Heater / Pump+Eco+Comfort / Not configured (installer mode only) |
| Pump control | Controller (C1) | Individual or common pump control (installer mode only) |
| Entity | Device | Created when |
|---|---|---|
| Gateway status | Gateway | Always — shows Online/Offline for the R-208 module |
| Status (controller) | Controller | Controller entities enabled in setup |
| Average room temperature | Controller | Controller entities enabled in setup |
| Controller relays | Controller | Installer mode off |
| Pump control | Controller (C1) | Installer mode off |
| Status (thermostat) | Thermostat | Always — shows alarm/error codes for each thermostat |
| Room temperature | Thermostat | Temperature sensor enabled in setup (default: on) |
| Floor temperature | Thermostat | Thermostat has an external floor probe |
| Humidity | Thermostat | Thermostat has a humidity sensor |
| Entity | Device | Created when |
|---|---|---|
| Valve | Thermostat | Valve sensor enabled in setup (default: off) — shows whether the actuator is open |
| Pump relay | Controller | Controller relay/IO sensors enabled in setup (default: off). Hidden for C2+ when pump control is set to Common |
| Boiler request | Controller | Controller relay/IO sensors enabled in setup (default: off) — shows Heat / Normal |
| Bypass (per room) | Controller | Installer mode off — read-only view of bypass state per room |
Entity names and sensor states are translated using Home Assistant's translation system.
The language used is the HA system language (Settings → System → General → Language),
not the individual user's profile language. Swedish (sv) and English (en) are supported;
English is the fallback for all other languages.
Sends a raw variable update to the Uponor API. Use with caution.
| Field | Required | Description |
|---|---|---|
var_name |
Yes | Variable name, e.g. sys_heat_cool_mode |
var_value |
Yes | Value to set |
device_id |
No | Target gateway device. Required if more than one gateway is configured. |
Returns raw hardware IDs and capability flags for every thermostat and controller as a service response, shown directly in Developer Tools → Services. Useful for identifying unrecognised device models and reporting them as issues.
Example output:
gateways:
- gateway_id: "101683"
gateway_model: R-208
controllers:
- controller: C1
sn_start: "4195"
hardware_type_raw: "0"
detected_model: X-245
sw_version: "1.22"
relays_config: "3"
thermostats:
- thermostat: C1_T1
sn_start: "2692"
hardware_type_raw: "0"
detected_model: T-145
has_humidity_control: 0
has_humidity_sensor: false
has_floor_temperature: false
is_public_device: 0
is_sensor_only: 0Returns the complete raw data dictionary received from the gateway as a service response, shown directly in Developer Tools → Services. Useful for inspecting all available variables and their current values — for example when trying to map an unknown variable or verify that a write has taken effect.
If more than one gateway is configured the response is grouped by gateway unique ID.
- Heat/cool mode switching applies to the entire system, not individual thermostats.
- The Uponor API does not expose an off command — see climate entity turn off behaviour above.
logger:
default: info
logs:
custom_components.uponorx265: debugFor the older Uponor X-165 module, see: https://github.com/dave-code-ruiz/uhomeuponor