Skip to content

Flag_Ext_Tele can only be cleared in exit_run_mode when motors are not being reversed (turtle mode)#179

Open
damosvil wants to merge 1 commit into
v0.22from
porting/exit_run_mode-keep-edt-flag-if-motor-direction-not-reversed
Open

Flag_Ext_Tele can only be cleared in exit_run_mode when motors are not being reversed (turtle mode)#179
damosvil wants to merge 1 commit into
v0.22from
porting/exit_run_mode-keep-edt-flag-if-motor-direction-not-reversed

Conversation

@damosvil

@damosvil damosvil commented Oct 5, 2023

Copy link
Copy Markdown
Contributor

Flag_Ext_Tele can only be cleared in exit_run_mode when motors are not being reversed (turtle mode)
That step is done in the lowest part of exit_run_mode

@damosvil damosvil self-assigned this Oct 5, 2023
@damosvil damosvil added the bug Something isn't working label Oct 5, 2023
@damosvil damosvil added this to the v0.21.0 milestone Oct 5, 2023
@damosvil damosvil changed the base branch from v0.21 to v0.22 October 24, 2023 16:10

@hyp0dermik-code hyp0dermik-code left a comment

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Confirmed that this fixes the bug described. Also thanks to Damosvil for the explanation, this flag should not be cleared until https://github.com/bird-sanctuary/bluejay/blob/80bd58803c50c0a9820634c2293101e299603e02/src/Bluejay.asm#L1073C22-L1073C22

at the earliest

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

bug Something isn't working

Projects

None yet

Development

Successfully merging this pull request may close these issues.

EDT safety arm prevents motors activating subsequent to turtle mode,configurator