The arm is a base yaw, three parallel pitch joints and a roll through the tool tip, so kinematics.py solves any tip position and tool tilt in closed form from the URDF. The new Cartesian group (Y) moves the tip along straight lines in base_link with the tilt fixed; LB keeps only the strongest axis. At a joint speed limit or the workspace edge the whole step shrinks, so the tip stops on the line, and the roll turns against the yaw to keep the tool's heading. Each drive now gets the next setpoint one period ahead and the speed that reaches it in exactly one period, measured from its encoder, so all drives arrive together. acc is 255 because a gentle drive ramp adds the same rpm/s to every drive and the one with the largest change falls behind. In simulation a sideways cut at 30:1 gearing stays within 7-17 um of the line, compared with up to 186 um with the old 1.5x speed rule. At the 1:1 placeholder gearing it stays within about 0.13 mm, one encoder count at the tip.
D-pad left/right changes the tool pitch while the tip stays in place, so the shoulder, elbow and wrist move around a fixed point. The tilt uses the same closed-form step as straight moves, so a joint limit stops it with the tip still in place. It runs at up to 30 deg/s, scaled by the speed level.
- Start is refused while a tilt button or A is held, like the sticks. - Homing clears the Cartesian rates, so releasing A can't resume the last move. - Cartesian roll ramps with the acceleration limit and scales with the accepted step. - The drives' setpoint one period ahead stays within the URDF joint limits, which the drive node now reads from robot_description. - If one drive would pass max_rpm, every drive slows by the same factor, so they still arrive together. - The roll compensation is documented as stopping the tool spinning about its own axis; that keeps a blade's heading only when the tool points straight down. - The Cartesian launch test is registered where it won't conflict with #22.
Reviewed in #24, which was merged into its stacked base after #23 had already been squash-merged into main, so it never reached main. This is the same change, applied to main. Drive the five joints with an Xbox controller through placeholder MKS SERVO42D/57D CAN drives, simulated until the real drives are connected. On Windows, a Python-only XInput bridge sends the controller state to the new wslg-teleop Compose service over UDP. The RViz camera follows the tool so the end of the arm stays in view; follow_camera:=false keeps a fixed view. teleop and joy_source use And/Or/Equals substitutions, so teleop:=True works like IfCondition. The new nodes receive use_sim_time, and the UDP receiver reads at most 100 packets per poll so a flood cannot starve its other callbacks.
On a busy CI runner the teleop node could still be loading the robot description when the test pressed Start, so the press was lost and the arm never moved. The test now sends idle packets until teleop reports its group and fresh controller input.
The tests could press Start before the teleop node had loaded the robot description or received controller input, so the press was lost on a busy machine. They now send idle packets until teleop reports its group and fresh input. Same fix as on #28.
A second robot_description replaced an enabled teleop with a disabled one without sending a hold, so the drives kept their last target.
absolute_axis rejected -0x800000, which the manual's 3-byte signed coordinate encodes. The node also capped the elapsed time it handed the drives at 100 ms, so a scheduler stall longer than the heartbeat never stopped a moving drive the way hardware would. The drive splits a long step into 10 ms motion steps and counts all of it toward the heartbeat.
Advance simulated heartbeat time before accepting new targets. Use MKS F5 zero-speed frames to stop moving drives and stop all drives on invalid targets. Handle ROS shutdown races without accepting failed node exits. Add controller, CAN, and launch regressions.
- `safety_interface.py` defines those topic, service, and row names in one place. The simulated source and future carrier-board source can share these constants. - `sim_safety_status_node.py` publishes the three topics and a `DiagnosticArray` using the established `name`, `level`, `message`, `value`, and `unit` fields. Its E-stop starts released and can be toggled with `/waybionic/safety/emergency_stop/set` (`std_srvs/SetBool`). The default 24 V reading is placeholder data, not a hardware limit. - `setup.py` registers the node as the `sim_safety_status` ROS executable; `package.xml` declares its `std_srvs` dependency. - `ground_station.launch.py` starts the simulator by default when teleop is enabled. `simulated_safety_source:=false` lets a carrier-board publisher take over later; the diagnostics topic follows the existing launch argument. - `DIAGNOSTICS_CONTRACT.md` records the proposed topics, types, rows, units, and status mapping. - `test_sim_safety_status_node.py` checks the emitted topic values and diagnostic rows, E-stop press/release behavior, and invalid voltage rejection. This change adds the simulated source and interface contract; it does **not** add the teleop Start interlock.
Three behaviours implemented: - E-stop pressed while enabled: the E-stop callback immediately disables teleop, publishes `teleop_enabled: false`, and sends a zero-velocity hold command. - Start while E-stop remains pressed: blocked, with an “Emergency stop pressed” note. - After release: it still requires a fresh Start press. Holding Start through the release does not re-enable teleop. - Treats stale/missing report as pressed.
…and teleop label. Also unit-tests the interlock without ROS and ads a launch test that toggles the simulated e-stop. Changes include: **Unit-Test Features** - `safety_interlock.py`: Extracts the E-stop policy into a standard-library-only class. It decides whether status is effectively pressed, reports why teleop is blocked, and provides display states. This allows testing the safety rules without importing or starting ROS. - `test_safety_interlock.py`: Tests the interlock without ROS: optional versus required missing/stale reports, reported pressed state, and recovery after a fresh release. - `test_xbox_teleop_node.py`: Adapts node tests to the extracted interlock and tests that its RViz label reports E-stop and voltage as unknown, released, pressed, stale, or provisional. - `test_simulated_estop_launch.py`: Launches the simulated safety node, calls its service to press and release the E-stop, and checks that both the Bool topic and diagnostics row reflect each state. - waybionic_teleop/CMakeLists.txt: No change in this diff; the new Python test is collected by the package’s existing pytest setup. - waybionic_bringup/CMakeLists.txt: Registers the new simulator integration test with `add_launch_test`. - waybionic_bringup/package.xml: Adds `std_srvs` as a test dependency because the launch test calls the `SetBool` service. **RViz Features** - `xbox_teleop_node.py`: Delegates E-stop decisions to the ROS-free interlock, subscribes to the existing supply-voltage topic, and adds both readings to the teleop marker label. Missing/stale required E-stop status is shown as fail-safe pressed. Voltage is labeled provisional; no thresholds are applied. - `mock_diagnostics_source.cpp`: Adds E-stop and 24.0 V provisional rows to mock Normal and Fault data, so the diagnostics panel shows these signals in its default mock mode as well as when live diagnostics provide them. - `test_ros_diagnostics_source.cpp`: Adds coverage that both mock modes include the released E-stop row and the provisional voltage row. - `waybionic_rviz_plugins/CMakeLists.txt`: Adds the mock diagnostics implementation to the existing test target so that the new C++ test can link it.
|
Important Draft PR not reviewedDraft PRs are not automatically reviewed by default.
To automatically review draft PRs, update your CodeRabbit configuration: reviews:
auto_review:
drafts: true
Thanks for using CodeRabbit! It's free for OSS, and your support helps us grow. If you like it, consider giving us a shout-out. |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Draft, opened so this work stays visible. The branch is from 10 October, by Malik and Yassin. It is 47 commits behind
mainand merging it conflicts in 20 files, because the teleop, drive and launch files it was built on have been rewritten since (#55, and the start-up guide in #57). It needs porting, not a merge. The diff below (19 files, +711/-23) is exactly its own work.What it does
The software side of the emergency stop: status, interlock and display. It does not replace the physical emergency stop, which must stay within reach of anyone near the arm.
safety_interface.py: the topic, service and row names in one place (/waybionic/safety/emergency_stop,/waybionic/power/motor_supply_voltage,/waybionic/safety/last_report_age), shared by the simulated source and a future carrier-board source.sim_safety_status_node.py: publishes placeholder E-stop, supply-voltage and report-age topics and aDiagnosticArray. The E-stop starts released and is toggled with the/waybionic/safety/emergency_stop/setservice. It stands in until the carrier-board node exists.safety_interlock.py: the policy, with no ROS in it. When the status is required, a pressed E-stop or a report that is missing or stale counts as pressed (fail-safe), with the reason and a display state (PRESSED,PRESSED-FAILSAFE,RELEASED,UNKNOWN,STALE).xbox_teleop_node.py): an E-stop pressed while enabled disables teleop at once and sends a zero-velocity hold. Start is refused, with a note, while it is pressed, and after release a fresh Start is needed (holding Start through the release does not re-enable). The teleop label and rumble keep running while the E-stop holds the arm, and the self-running demo holds while it is pressed.DIAGNOSTICS_CONTRACT.md).test_safety_interlock.py(no ROS),test_sim_safety_status_node.py,test_simulated_estop_launch.py(toggles the simulated E-stop in a launch), and cases intest_xbox_teleop_node.py,test_autoplay_node.pyandtest_ros_diagnostics_source.cpp.Why it stalled
TODO(hardware-TBD)for both (carrier_bridge.ino,BenchTelemetry.h), so only the simulated source exists. The real carrier would have to publish the same topics.To revive it
mainafter Add the arm start-up guide, joint switch-off and Mac/Windows launchers for the real arm #57, Add chicken head and demo motion modes with a Motion modes panel #58 and Open the joint limits to where the arm's parts meet #44. The teleop node is the main work: the start-up guide's locked and switched-off joints and the chicken head and demo modes must also stop and hold on an E-stop.