Good research, Gianna: the camera design, the Orbbec Gemini 2 recommendation, the controller comparison and the input mapping are all useful. A few points before it can merge:
docs/camera-research/README.mdline 30 says the latency should "remain consistently >30-50ms". It should be below 30 to 50 ms.- Line 11 links to
doctor_camera_system_design.mdon your branch, which breaks after the merge. Please use a relative link. - Spelling: Electrial, seperate, attatched, exaxtly, ergonimic and qual-core.
- Please add the measured delay. Run the doctor-view feed from #36 with a USB webcam for five minutes, at 1080p and 30 fps if the camera supports it, and report the average, minimum and maximum delay and the jitter, with a stopwatch cross-check. Note which numbers depend on the webcam rather than the Gemini 2.
Then re-request a review.
yassinsolim
left a comment
There was a problem hiding this comment.
Thanks, Gianna. Points 1 to 3 are fixed: the latency target, the relative link and the spelling. One new typo: doctor_camera_system_design.md has a double space in "Directly attached to arm".
Point 4 is still open. Add the measured delay from the doctor-view feed, which is on main now (camera:=true). Then re-request a review.
yassinsolim
left a comment
There was a problem hiding this comment.
Thanks, Gianna. The five-minute run is what I asked for, and the disconnect and reconnect notes are a good addition. Three small fixes and it's ready:
- Stopwatch check. It says a 0.68 ms difference but calls it high latency, and the photo shows the doctor view behind the timer. If it's 0.68 s, write that, and add a line on why it's so much bigger than the 21.6 ms average: the monitor measures from when the bridge reads a frame from the camera to when the ground station receives it, while the stopwatch also includes the camera, the virtual webcam app and the screen.
- Resolution. Add the resolution and frame rate the bridge ran at.
- Typos: "recieving", and "negative frames" should probably be "negative delays".
The CI failure is a flaky teleop launch test, not your docs.
ovilikaris-dotcom
left a comment
There was a problem hiding this comment.
Reviewed commit 28b213d. The automated CI checks pass, and the documentation provides useful camera research.
However, two corrections are required before approval:
- Correct and verify the stopwatch latency measurements and units.
- Distinguish the Gemini 2 depth resolution from its RGB resolution.
I've added inline comments identifying both issues. Please address these before merging.
|
|
||
| ## Five Minute Experiment Results | ||
| ### Ran at 1280x720 at and average of 30fps | ||
| - Taking a picture of the timer and the doctor view, there is a **0.54ms** difference in the timer. |
There was a problem hiding this comment.
The stopwatch measurement appears to have incorrect units. The recorded difference is 0.54 seconds (540 ms), not 0.54 ms.
Please verify the original stopwatch images for both experiments (lines 8 and 18), correct the units, and ensure the measurements are consistent throughout the document.
| Here is the documentation on the [Orbbec camera and OpenCV](https://docs.opencv.org/4.13.0/d1/d33/tutorial_orbbec_uvc.html) | ||
|
|
||
| ## Limitations | ||
| - The maximum resolution would be 1280 x 800 and its maximum frame rate would be up to 30fps. |
There was a problem hiding this comment.
The resolution specification needs clarification. According to Orbbec's Gemini 2 specifications, 1280 × 800 refers to the depth resolution, while the RGB camera supports 1920 × 1080 at 30 FPS.
Please distinguish the depth and RGB resolutions rather than describing 1280 × 800 as the camera's overall maximum resolution.