Known limitations

This repository is at version 0.1.0, the first release after the public preview. The engine behind it has run real plants, but this public form of it (the host, the web editor, the contracts, the sample WMS and the guides) is new, and before 1.0 a minor version may change it in incompatible ways (versioning and compatibility). This page lists what the WCS does not do, or does only partly, today. Each point was checked against the code of this repository.

Three ways of using the WCS appear throughout these guides:

  • demo: one machine, the sample WMS, the loopback driver, nothing physical;
  • test bench (commissioning): a real WMS adapter and, step by step, real machines, with people watching the plant and nobody depending on it yet;
  • production: the plant works on it.

Most limits below matter only for production; the table says where.

Summary

Limit Matters for More below
A fact the WMS refused for good is parked, and there is no API to inspect, retry or discard it test bench, production Parked facts
One shared full key and one optional read-only key: no per-operator identity, no roles production Authentication and identity
A key change takes effect only at the next start of the host production Authentication and identity
Importing a plant does not rebuild the driver connections: Run is refused until command 1003 test bench, production Plant import and connections
No driver for real machines is included test bench, production Drivers
Windows 11 x64 is verified; Windows Server, Linux and ARM64 are not all Platform
No published hardware requirements; wcs.db keeps every command and grows without bound production Sizing and growth
Little is observable from outside: parked facts and queue backlogs only through Wcs.DbTool verify, no write-queue counters in the API test bench, production Monitoring
The web editor needs the Development environment or a published host all The web editor
One host per plant: no clustering, no failover production Availability
Host messages and logs are partly in Italian all Language
Source-only: no NuGet packages, the libraries are referenced from a clone or submodule at a tag all Distribution
Wcs.Viewer is experimental: no sample, no tests, outside the compatibility rules all Wcs.Viewer

Parked facts towards the WMS

The WCS reports physical facts to the WMS through durable queues in wcs.db (facts, durable queues and receipts). A temporary failure (no answer, a timeout, a 5xx, a 408 or 429) is retried for ever, with a growing pause. A permanent refusal (any other 4xx; for the load-unit transitions also a stored payload the WCS cannot read back) is parked: the row stays in its queue with its reason and is never sent again, not even after a restart.

Three queues park:

Queue (table in wcs.db) Route What a parked row holds back Host log line (Error)
PendingWarehouseTransitions load-units/allocate, load-units/release every later fact about the same load unit; a parked release also every later allocation of any load unit. The mission is not closed, and the device holding the load unit goes to Warning Transizione WMS {operationId} ({Kind}, UDC {id}) RIFIUTATA DEFINITIVAMENTE e parcheggiata: ...
PendingCellGiveBacks reservations/release-load-unit-cell nothing else; the cell stays reserved in the WMS ... la restituzione della cella {id} ... e' stata RIFIUTATA DEFINITIVAMENTE dal gestionale e resta parcheggiata ...
PendingPickedExtractionReports assignments/picked-extraction-became-deposit nothing else; the order is not reopened in the WMS ... la riapertura dell'ordine ... e' stata RIFIUTATA DEFINITIVAMENTE dal gestionale e resta parcheggiata ...

What is missing. There is no API, command or editor page to list parked rows, see their error and payload, retry them after the cause is fixed, or discard them. A parked load-units/allocate or load-units/release therefore stays until someone intervenes, and while it stays it keeps the load units that depend on it waiting.

What to do today (the supported procedure until an administration flow exists):

  1. Keep the host running and the data folder untouched. Do not edit or delete rows in wcs.db by hand: the queues are read in order and depend on each other, and a hand-edited row can let a later fact reach the WMS before the one it depends on.
  2. Copy the log line: it carries the operation id, the kind, the load unit and the reason the WMS gave.
  3. Fix the cause on the WMS side (usually the adapter answering 4xx to something it should accept, or 4xx for a temporary problem, which must be 5xx).
  4. For a parked cell give-back, free the cell in the WMS; for a parked picked-extraction report, put the order right in the WMS. These two hold nothing else back in the WCS.
  5. For a parked load-units/allocate or load-units/release, open an issue on the repository with the log line (without customer data or keys), or contact Sun Tech (https://www.suntechonline.it) for a plant under a support agreement. Restarting the host does not release a parked row.

To avoid parking in the first place: answer 4xx only for a request that can never succeed, 5xx for anything that may work later, and keep a receipt per OperationId so that a repeated request gets the first answer again (the WMS contract). On a test bench, check the host log for RIFIUTATA DEFINITIVAMENTE after every test run. The log line is written once, when the fact is parked; the count of parked rows that Wcs.DbTool verify prints still shows it after a restart. Both are checked by the monitoring scripts.

Authentication and identity

  • The host knows two static keys: Wcs:ApiKey (everything) and, optionally, Wcs:ReadOnlyApiKey (GET requests and the event hub only). Every program and every person using the same key is the same caller to the host.
  • No per-operator identity. The web editor asks for a key, not for a user; its edit lease is held by a random id of the browser session. The userId and workstationId fields of a command are written by the caller and are not verified. The operators' log says what happened, not who did it.
  • No roles beyond full and read-only: whoever has the full key can start and stop the engine, send any command and replace the plant.
  • Key rotation needs a restart. appsettings.Secrets.json is reloaded by the configuration when it changes, but the host reads its own keys and the WMS key once, at start: a new key is accepted, and the old one refused, only after the host is restarted.
  • Failed authentications are answered 401, but not logged, and there is no rate limiting or lockout.

See security and threat model.

Plant import and connections

PUT /api/v1/plant/graph replaces the plant in wcs.db but does not build the driver connections. After an import that adds devices of connection type Connected, or driver settings, reload the plant with command 1003 (engine in Stop) or restart the host; until then Run is refused and the devices without a connection are set OffLine (when connections are built).

Drivers

The only driver in this repository is the loopback driver, which simulates the machines in the process (connection type Test). Sun Tech's driver for its PLCs, and the protocol it speaks, are proprietary and not included; they are available from Sun Tech. Any other driver is to be written against IConnection and IConnectionFactory (connecting machines). The driver contract has no method to halt a movement already sent to a machine.

The loopback driver never raises the field events (NewLuOnAsi, LuUnloadedFromAsi, AsiRequestsLuInfo, AsiEvent): with it, load units enter with command 3002 and leave with command 2004. What it proves is that the WCS's logic runs; it proves nothing about real machines or about safety (SAFETY.md).

Platform

The WCS is built and tested on Windows 11 x64 with the .NET 10 SDK. The host targets net10.0 and its path has no Windows-only call, but Windows Server, Linux and ARM64 have not been verified, and Sun Tech has not yet published an official support matrix. The host runs as a Windows service with UseWindowsService; its warnings and errors also go to the Windows Event Log. Component by component, with the evidence: supported platforms.

Sizing and growth

  • No hardware requirements are published: no configuration has been measured for this release. Size from a capacity test on your plant (performance and sizing).
  • wcs.db grows without bound: no code deletes command rows, so every command ever queued stays in it. Watch its growth (monitoring).
  • The PLC log is pruned by the driver, not by the host: the host keeps two monthly files, and rows inside the current one are deleted only when the field driver asks for it (ClearMessagesOlderThanAsync). A driver that never asks keeps a month of messages per file.

Monitoring

The host API has no health route beyond GET /api/v1/status. Parked facts and the backlog of the durable queues towards the WMS can be read only with Wcs.DbTool verify; the engine's counters of dropped or failed database writes are not exposed; the SignalR hub is not a persistent health check. What can be watched today, and scripts for it: monitoring and alerting.

The web editor

The web editor's static files are served next to the executable only by a published host (dotnet publish). A host built with dotnet build serves them only in the Development environment; elsewhere the /editor page stays blank and the host logs a warning at start (deployment). The editor's pages load without a key and do nothing until a key is entered.

Availability

The engine keeps its state in memory and in SQLite files under one data folder: run one host per plant. There is no clustering, replication or automatic failover. Plan backups and a tested restore (backup, restore and disaster recovery).

Language

Many host messages (error titles and details, log lines) are in Italian, and so are many comments in the engine and the host, and the historical notes. The guides quote the messages and translate them. Program against status codes, not texts.

Distribution

The WCS is distributed as source. No NuGet package of the contracts and clients (Wcs.Wms.Contracts, Wcs.Api.Contracts, Wcs.Api.Client, Wcs.Common, Wcs.Connection.Interface) is published yet; they will come with a later release. Until then a WMS adapter, a client program or a driver references the projects from a clone of this repository, or a git submodule, checked out at a release tag (README). The releases carry the published host, Wcs.DbTool and the sample WMS, framework-dependent and built on Windows (release process).

Wcs.Viewer

WCS/Wcs.Viewer, a library that keeps a read-only copy of the engine state from the hub, is experimental. Its WinForms test bench is not published, so it has no tests and no sample here; no guide relies on it, and it is outside the compatibility rules: it may change or be removed in any release. To follow the engine from your code, use Wcs.Api.Client and its PlantEventsConnection (the host API).

Smaller points

  • Command 3001 (MoveLuAutomatic) is reserved: it is accepted and marked Done without doing anything.
  • The operators' log records command 3002 with the wording of an unload; nothing is unloaded.
  • Wcs:Engine:DiscardLuManagedInWarehouse is read at start and used by nothing.
  • The edit lease lasts 60 seconds and is renewed by every authorised write; a single write that takes longer than that (a very slow disk), or a browser tab closed while a save is in flight, can let a second holder write at the same time.
  • The OpenAPI document (/openapi/v1.json) is served without a key in every environment except Production.
  • The sample WMS keeps everything in memory and has a public key: it is for the demo and for tests, never for a plant.