Which operating systems, processor architectures, browsers and .NET SDK each part of the WCS has been
run on for 0.1.0, and with what evidence. This page states what was verified; it is
not a promise of support. Sun Tech has not yet published an official support matrix: until it
does, nothing here is "officially supported", and the open points are listed in the
publication checklist.
| State | Meaning |
|---|---|
| Tested | the component's build and its test suite ran green on that platform, as described under evidence |
| Expected to work, not verified | nothing in the code or its dependencies is known to prevent it, but nobody has run it there for this release |
| Experimental | runs, but is outside the compatibility rules and has no tests here |
| Unsupported | known not to work, or deliberately out of scope |
| Not applicable | the combination does not make sense (a library has no browser, a test project is not deployed) |
"Expected to work" is a reading of the code, not a test result: do not plan a production installation on it without running the test-bench checks on that platform first.
| Component | Windows 11 x64 | Windows Server x64 | Linux x64 | Windows or Linux ARM64 | Browser | Notes |
|---|---|---|---|---|---|---|
Wcs.Host (engine, API, hub) |
Tested | Expected to work, not verified | Expected to work, not verified | Expected to work, not verified | Not applicable | runs as a Windows service with UseWindowsService; elsewhere as a plain process |
Wcs.WebEditor (served by the host) |
Tested, with the host | as the host | as the host | as the host | Chromium: Tested (Playwright). Edge and Chrome: Expected to work, not verified. Firefox, Safari: not verified | Blazor Server plus the draw.io bundle, running in the browser |
Wcs.DbTool |
Tested | Expected to work, not verified | Expected to work, not verified; restore needs --assume-stopped there |
Expected to work, not verified | Not applicable | |
Wcs.Api.Client, Wcs.Api.Contracts |
Tested | Expected to work, not verified | Expected to work, not verified | Expected to work, not verified | Not applicable | net10.0 libraries |
Wcs.Wms.Client, Wcs.Wms.Contracts |
Tested | Expected to work, not verified | Expected to work, not verified | Expected to work, not verified | Not applicable | net10.0 libraries |
Wcs.Connection.Interface |
Tested (through the engine and host suites) | Expected to work, not verified | Expected to work, not verified | Expected to work, not verified | Not applicable | the contract only; a driver brings its own platform limits |
Wcs.Connection.Test (loopback driver) |
Tested (through the engine, host and end-to-end suites) | Expected to work, not verified | Expected to work, not verified | Expected to work, not verified | Not applicable | simulates the machines in the process |
| a field driver (Sun Tech's or yours) | depends on the driver | depends on the driver | depends on the driver | depends on the driver | Not applicable | see field drivers |
Wcs.Viewer |
Experimental | Experimental | Experimental | Experimental | Not applicable | no tests, no sample; see Wcs.Viewer |
bUnit tests (Wcs.WebEditor.Test) |
Tested | Not applicable | Expected to work, not verified | Expected to work, not verified | none (bUnit runs no JavaScript) | |
Playwright tests (Wcs.WebEditor.Browser.Test) |
Tested, Chromium | Not applicable | Not verified (the suite starts Wcs.Host.exe; its README describes the Windows setup) |
Not verified | Chromium only | needs a built host and playwright.ps1 install chromium |
Sample WMS (samples/Wcs.SampleWms) and its tests |
Tested | Not applicable (never for a plant) | Expected to work, not verified | Expected to work, not verified | Not applicable | demo and tests only |
.NET SDK: the one pinned by global.json at the root of the repository, 10.0.402, with
rollForward: latestPatch (a later patch of the same feature band is accepted, previews are not).
The released binaries are framework-dependent and need the .NET 10 runtime (ASP.NET Core Runtime 10 for
the host and the sample WMS, .NET Runtime 10 for Wcs.DbTool) (release process).
Windows Server: no Windows Server version has been run for this release, so none is listed as Tested. The host uses nothing that Windows 11 has and Windows Server lacks, as far as the code shows, but that is a reading, not a test.
| Evidence | What it covers | Kind |
|---|---|---|
| Local runs on Windows 11 Pro for Workstations, x64, .NET SDK 10.0.402, in October 2026, while this release was prepared | on a clean clone of the public repository: the build of every project, the suites of the engine, the host and the web editor (bUnit), and the quick start. On 2026-10-15: the suites of the clients and contracts, Wcs.DbTool, the link checker, the contract checker and the sample WMS end to end (with the monitoring scripts), and the browser suite with Chromium (284 tests) |
observed on the local machine |
GitHub Actions workflows (ci.yml, browser.yml, release.yml), every job on windows-latest |
the same suites on every pull request and before a release | automatic, once the repository runs them on GitHub |
| The test suites themselves | what each suite asserts; a suite proves nothing about a platform it has not run on | automatic |
windows-latest is a label GitHub moves from one Windows Server image to the next; the image a run
used is printed at the top of its log. A green run there is evidence for that image only, and for the
x64 runners GitHub provides; it says nothing about Windows 11 on ARM64 or about Linux.
Until the workflows have run on the public repository, the only evidence is the local one. Who checks the first runs, and where the results are kept, is in the publication checklist.
Every project under WCS/, samples/ and tools/ targets net10.0, not net10.0-windows; the three
shared libraries under Common/ (Helper, Log.Interface, Log.Windows) target both. The parts that touch Windows:
| Part | Windows-specific piece | Used by | Off Windows |
|---|---|---|---|
Wcs.Host |
UseWindowsService (service name Wcs.Host) |
the host | does nothing: the host runs as a plain process |
Wcs.Host |
the ASP.NET Core Event Log provider, added by the default host builder on Windows | the host's warnings and errors | absent: the host logs to the console only |
Common/Log.Windows |
targets net10.0 and net10.0-windows10.0.19041.0; writes the Windows event log with System.Diagnostics.EventLog |
Wcs.Viewer only (the host does not use it) |
the writer does not create or use EventLog; WriteLog still emits its debug trace |
Common/Helper |
targets net10.0 and net10.0-windows10.0.19041.0; an internal RSA helper uses RSACryptoServiceProvider, CspParameters and WindowsIdentity |
the engine references the library; nothing in the WCS calls that helper | not reached |
Wcs.DbTool restore |
the check that no process holds the data files open | restore |
not available: restore refuses unless --assume-stopped says the host is stopped |
The release check performs a clean build with warnings treated as errors. Windows-only calls in
Common/Log.Windows are guarded by OperatingSystem.IsWindows(); Common/Helper's internal RSA
helper is compiled for its platform-specific target and is not reached by the WCS. A platform warning
therefore fails release validation instead of being accepted as known residue.
The SQLite engine is a native library (e_sqlite3, from SQLitePCLRaw). A framework-dependent
publish without a runtime identifier, as the release does, carries it for many platforms under
runtimes/<rid>/native/, among them win-x64, win-arm64, linux-x64 and linux-arm64 (observed
in the build output). That makes ARM64 and Linux possible; it does not make them tested.
The driver is the part most likely to tie an installation to one platform:
- Sun Tech's driver for its PLCs is proprietary and not in this repository. Its platforms are declared by Sun Tech, not by this page; ask before planning anything other than Windows x64.
- A driver of your own is loaded from the host folder through
Wcs:ConnectionFactory(connecting machines). If it uses a vendor library (a PLC communication DLL, an OPC or fieldbus stack), that library decides: many are x64-only, some Windows-only, and an x64 native DLL does not load in an ARM64 process. Check every native dependency of the driver for the target architecture before choosing the hardware. - Emulation is not a test: an x64 process running under emulation on Windows ARM64 is a different setup from a native ARM64 process, with its own timing. Neither has been run for this release.
WCS/Wcs.Viewer keeps a read-only copy of the engine state from the hub. It is experimental: its
WinForms test bench is not published, so it has no tests and no sample here, and it is outside the
compatibility rules. It writes its warnings to the Windows event
log through Common/Log.Windows. Use Wcs.Api.Client and its PlantEventsConnection instead
(known limitations).
A prudential recommendation, not a requirement of the code:
- Build and run the suites on that platform (
dotnet testfor the engine, host, bUnit, clients and sample WMS; the browser suite if the web editor matters). - Run the quick start and the backup and restore test there.
- With a field driver, run its connection-loss and reconnection tests on the target hardware.
- Run the capacity test of performance and sizing on the target hardware.
- Keep the results: they are the evidence a future version of this matrix needs.