Reworks how code-based pairing attempts are gated, from the #183 lockout discussion.

Dynamic pairing code: the persisted failure counter and its escalation to gesture-gating are gone. A failed attempt is one where the client started emitting the code and the attempt ended without a successful server_kc verification. After 20 consecutive failed attempts the client MUST hold attempts back until a deliberate, manufacturer-defined operator action; which action is the manufacturer's choice, with guidance tracked in #205. The count is global across servers and addresses and resets on success or on that action. How a client paces attempts before the limit is its own choice, and it MAY be stricter, including a gesture from the first attempt. Since any deliberate action qualifies, no device is locked out, and since a client with no limit is not conformant, manufacturers have a spec section to point a test lab at (ETSI EN 303 645 provision 5.1-5, EN 18031-1 AUM-6).

Static pairing code: the window admits up to 5 attempts instead of one, all on the connection that carries the first, so a typo no longer costs a walk to the device. It closes on a completed pairing, the fifth failed attempt, drop of that connection, operator cancellation, or lifetime expiry, and the lifetime pauses while an attempt is in progress. The pairing window is now a static-code-only concept and its section moves under the Static Pairing Code Flow.

client/pair-pending now covers both cases, a gesture awaited or a dynamic attempt held back, and gains an optional message: a plain-text sentence for the operator of at most 200 characters, preferably in one of the server's languages, shown as device text with no markup interpreted. The server SHOULD surface the pending state and the message to the operator and apply its own timeout.

An abandoned attempt does not count against a window and counts as a failed dynamic attempt only if the code was already being emitted.

@maximmaxim345 maximmaxim345 left a comment

Copy link
Copy Markdown
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Have two security concerns with this PR, left inline comments for both of them.

Comment thread pairing.md Resolved
Comment thread pairing.md Resolved

balloob commented Sep 1, 2026 •

Copy link
Copy Markdown
Contributor

Two UX gaps this PR opens or leaves, from reading the combined result of #183, #189, and this branch. One UX gap this PR opens (edited: struck the parts that turned out wrong, see the note at the end).

client/pair-pending now means two different things and the server cannot tell them apart. Before, pending meant one thing: a gesture is awaited. After this change it also means "in backoff, wait up to 15 minutes". The message still carries only pairing_index, so the server has to show the same generic waiting state for "walk to the device and press the button" and "come back in twelve minutes". The interplay with the server-side timeout is the problem: the server SHOULD time out while waiting for client/pair-init, and any sane timeout is shorter than a 15-minute backoff, so "pair-init follows once the backoff elapses" will almost never happen on the activation that saw the pending. The operator sees a generic failure, retries, hits backoff again, and nothing ever says why. Suggest adding reason: 'gesture_required' | 'backoff' and, for backoff, retry_after_s (the client knows the cooldown it applied) so the server can render an actionable state and size its own timeout.

The static pairing window still dies on connection drop. The window now admits five attempts, which is the right fix for typos. But "drop of the connection carrying its attempts" still closes it, so one Wi-Fi blip mid-pairing sends the operator back to the device to press the button again. The gesture proved presence; a transport hiccup does not un-prove it. Letting the window run to its lifetime across a reconnect (the client already tracks it locally; nothing on the wire changes) would remove that walk.

Edit: the reason field is redundant - after this PR, pending on static_pairing_code always means a gesture and pending on dynamic_pairing_code always means backoff, and the server picked the method. And the window must keep closing on connection drop: static pairing runs on the Sentinel PSK, so a reconnecting server cannot be verified as the same one, and close-on-drop is what keeps the window bound to the connection that was admitted when the operator gestured. Only retry_after_s stands.

Dynamic pairing code: replace gesture-gated escalation with a time-based backoff after 5 failures, and drop the counter's persistence across reboots - rebooting requires the same physical presence a gesture proves. Static pairing code: the window admits up to 5 attempts per gesture instead of one, so a typo no longer costs a walk to the device. The pairing window is now a static-code-only concept.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
@balloobbot
balloobbot force-pushed the pairing-gating-rework branch from 5390ded to 8260423 Compare September 2, 2026 13:14
@marcelveldt

Copy link
Copy Markdown
Contributor

Good example of something to add to the implementation guide.

cooldown strategy should be client concern so we should not mandate it at all

No escalation and no backoff: how a client throttles failed dynamic pairing attempts is its own concern.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
@marcelveldt marcelveldt added this to the 1.0.0 milestone Sep 2, 2026
@arturpragacz

arturpragacz commented Sep 2, 2026 •

Copy link
Copy Markdown
Contributor

The change to static pairing code to 5 attempts per window is fine.

The change to dynamic pairing code going from gesture-gating after escalation to cool down is not a good idea. We could, if anything, in light of the other changes go in the opposite direction now and gesture-gate already from the first attempt.

@maximmaxim345

Copy link
Copy Markdown
Member

The change to dynamic pairing code going from gesture-gating after escalation to cool down is not a good idea. We could, if anything, in light of the other changes go in the opposite direction now and gesture-gate already from the first attempt.

@arturpragacz was thinking about this a bit. What I'm definitely against is 3067218 in its form. That's basically dropping the constants were IMO good enough, so a client implemented to spec can be brute forced in under a day.

Gesture gating is a good idea, but forcing it onto any manufacturer also feels invasive. What I'm fearing is that we have a protocol thats secure, but with limited adoption because of that. I think there is no "best" solution here so we need to compromise somewhere...
And in addition what we also need to factor in: Its very probably that spoken digits are a niche pairing mechanism. Almost all manufacturers have their own App where they want to be in full control and we will not be able to change that.

I have another idea though that should allow security conscious devices to stay secure (or even more secure as before this PR and other recent changes), but still allows manufacturers more flexibility. What do you think about ce32049:

What if we keep client/pair-pending for the dynamic flow and add two optional fields, retry_after_ms and message? Then the client can do whatever it wants (gesture from the first attempt, require a gesture after x attempts, cooldown after 5) and the server can actually show what's going on: a countdown, or "press the button on the bottom of the device".

With the recommended cooldown from ce32049, from my calculations it's a 50% chance of getting in after ~20 years. With no limit it's about 20 ms per attempt, so a 98.7% chance of getting in within a day.
Ok, before this PR it was required to be considerably more safer, but we don't have the management activity anymore so the attack surface is also a lot smaller now.

As written a client with no limit at all is conformant, a server that
aborts before the code finishes playing is never counted, and a count
kept per server is bypassed by rotating keys. After 20 consecutive
failed attempts the client now MUST hold attempts back until a
deliberate operator action, with a power cycle qualifying so no device
is locked out. Counting starts when emission starts and the count is
global. The cooldown schedule is dropped: how a client paces attempts
before the limit is its own choice, reported through `retry_after_ms`
and `message`. Also caps `message` at 200 characters and lets a server
cancel instead of outlasting `retry_after_ms`.
Comment thread pairing.md Resolved
Comment thread pairing.md Resolved
Comment thread pairing.md Resolved
Comment thread pairing.md Resolved
With no recommended cooldown and a hard stop at 20 attempts the
duration served no security purpose, and `message` already tells the
operator what the client waits for.
@balloob
balloob merged commit 12f50a8 into Sendspin:main Sep 7, 2026
1 check passed
maximmaxim345 added a commit that referenced this pull request Sep 10, 2026
Removes the digit audio pack that #173 introduced. During initial
pairing the pack came from an unauthenticated peer, which thereby chose
what the client's speaker played and drove the client's audio decoders
before any trust was established. Speaking clients return to their own
bundled voice, choosing the language against the server's `languages`
hint in `server/hello` under RFC 4647 Lookup matching, as before #173.

Hand revert rather than `git revert`: #179, #194 and #237 have since
rewritten the surrounding text, and the `languages` move from
`server/activate` to `server/hello` in #173 stays, since
`client/pair-pending`'s `message` field relies on it.

Changes, all in `messaging.md` and `pairing.md` with `README.md`
regenerated:

- Binary message ID `2` returns to the reserved `2-3` range.
- `server/activate` `pairing.format?` no longer conditions `digits` on
fitting a pack.
- Sequence diagram, Digits emission, Protocol Errors, the
`dynamic_pairing_code` descriptor (`digit_audio` removed; `out_channels`
unchanged), the Messages intro, `client/pair-init` and
`server/pair-init` lose their pack references.
- The `Server → Client: Digit Audio Clip (Binary)` section is removed.

Closes #203

---------

Co-authored-by: Maxim Raznatovski <nda.mr43@gmail.com>
maximmaxim345 added a commit to Sendspin/sendspin-js that referenced this pull request Oct 27, 2026
# What does this implement/fix?

<!-- Quick description and explanation of changes. -->

A mistyped dynamic pairing code ended the whole pairing attempt, and
after 10 failures every attempt needed the pairing window, with no way
to reset the count.

Now a wrong code starts another round with the same code. After 20
rounds without a correct code, attempts wait until the app calls
`releasePairingHold()` on a deliberate action on the device, which also
resets the count.

This also fixes a few other gaps with the spec:
- The static pairing window now stays open across attempts, so a
timed-out or cancelled attempt no longer needs a new gesture. It closes
on a completed pairing, the fifth wrong code, a drop of the connection
that used it, or `cancelPairing()`.
- Pairing messages that arrive out of sequence now close the connection
instead of being ignored. Messages still in flight after the client's
own `pair/abort` are still dropped.
- The sample player shows the dynamic code as `123-456` and speaks it
with a pause between groups.

This is a breaking change: `isDynamicPinEscalated()` is now
`isRoundLimitReached()`, and `releasePairingHold()` replaces
`openPairingWindow()` for releasing held-back dynamic pairing attempts.

**Related issue or spec PR (if applicable):**

- Sendspin/spec#194
- Sendspin/spec#237
- Sendspin/spec#312

## Types of changes

<!--
Tick exactly one box. CI (.github/workflows/pr-labels.yaml) applies the
matching label, and the release notes use it to sort this change.
-->

- [ ] Bugfix (non-breaking change which fixes an issue): `bugfix`
- [ ] New feature (non-breaking change which adds functionality):
`new-feature`
- [ ] Enhancement to an existing feature: `enhancement`
- [x] Breaking change (changes the public API or the protocol in a way
that is not backwards compatible): `breaking-change`
- [ ] Refactor (no behavior change): `refactor`
- [ ] Documentation only: `documentation`
- [ ] Maintenance / chore: `maintenance`
- [ ] CI / workflow change: `ci`
- [ ] Dependencies bump: `dependencies`
kahrendt pushed a commit that referenced this pull request Nov 5, 2026
<!-- Describe the change and why it is needed. -->

A recognized message can carry a value outside its field's fixed range,
such as `output_delay_ms` above 5000 in `client/state` or a controller
`volume` of 101. Most fields don't say what the receiver does with one.

This makes such a value a protocol error, and the receiver MUST close
the connection. Only a broken implementation sends one, and closing
matches how the spec treats other protocol errors. The rule only covers
fixed ranges and length limits. Bounds relative to another value, like
the visualizer `rate_max` or the player timing bounds, can be crossed by
a message in flight, and the receiver often can't check them reliably. A
field or message with its own rule keeps it: the server still ignores a
`seek` outside 0 to `seek_max_ms`, a bad `client/init` is still an init
failure, and the #344 `client/hello` caps keep their MAY close.

This also removes handling the rule now covers:
- truncating an over-long server `name` or `group_name` (from #339) and
`client/pair-pending` `message` (from #194)
- the SHOULD close for an artwork `channels` array longer than 4
- the player clamp rules for `output_delay_ms` and `min_buffer_ms`,
since their 0-5000 field ranges already bind the sender

It also adjusts text the rule would otherwise break:
- an artwork client that truncates its `channels` array keeps at least
one entry
- metadata `track` states its range (at least 1), and `year` no longer
says "YYYY format"
- values inside ignored inactive-role objects are left unvalidated
- sending a value outside a range or length limit an earlier revision
defined needs negotiation, like a new field

So plain text over its byte cap now closes the connection too, including
a client `name` or `device_info` string over 64 bytes.

- [x] I accept the [Contributor License
Agreement](../blob/main/CONTRIBUTOR-LICENSE-AGREEMENT.md) for this
contribution.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.