Skip to content

Latest commit

 

History

History
362 lines (302 loc) · 20.8 KB

benchmark-methodology.md

File metadata and controls

362 lines (302 loc) · 20.8 KB
myst
html_meta
description keywords
How AgentKernelArena measures GPU kernels with CUDA or HIP Graph replay, records event fallbacks, and compares matched benchmark cases.
AgentKernelArena, benchmark, CUDA Graph, HIP Graph, CUDA event, HIP event, Triton, FlyDSL, kernel timing, speedup

Performance measurement methodology in AgentKernelArena

AgentKernelArena uses graph-first device timing for Python-callable GPU kernels, regardless of whether the kernel is implemented in Triton, HIP, FlyDSL, or PyTorch. The canonical implementation is src/tools/perf/aka_benchmark.py. PyTorch exposes CUDA and ROCm through the same torch.cuda namespace, so benchmark_method: cuda_graph means CUDA Graph on a CUDA build and HIP Graph on a ROCm build.

Schema-v3 kernel tasks

Kernel tasks (see the task contract) use one timing method in every language. Each call to run() is captured into a CUDA graph and timed per replay after a 1 GiB cache flush (benchmark_cuda_graph_cold_cache_samples: 10 warmups, 100 samples, median). The two framework input draws alternate between samples, and every timed sample's outputs are checked. There is no Event fallback for these tasks: a baseline that cannot be captured on the current stream fails the QA audit (QA-TIMING-METHOD), and each performance case must take the baseline at least 10 us (QA-TIMING-FLOOR). The final evaluation remeasures the baseline interleaved with the candidate, and the task's speedup is the geometric mean of the per-case speedups (baseline time over candidate time). The remaining sections of this page describe the shared helper and the older fallback and cold-weight policies, which apply to the end-to-end and legacy helper paths.

Canonical Python API

The canonical implementation is src/tools/perf/aka_benchmark.py, which the schema-v3 evaluator uses for kernel tasks. Its ReadOnlyCacheFlush uses a reusable initialized 1 GiB read sweep, after input preparation and before the start Event of every single-operator graph replay. The resulting cuda_graph_cold_cache metric is an Event graph span with eviction excluded. It is distinct from the legacy warm cuda_graph method below, profiler kernel-duration sums and cuda_graph_cold_weights rotation. Explicit migrations need fresh paired measurements and GPU qualification; this addition does not change historical task policies or scores.

Cold-cache performance case rows must put the returned timing metadata under metadata, with benchmark_method and execution_time_ms on the case row. The protocol checks the cache policy, metric, one invocation per replay and eviction byte count; comparison rejects differing or missing cache identities. The reference's paired utility preserves raw samples and reports a geometric mean speedup with a paired-round 95% percentile-bootstrap interval. It is a diagnostic comparison, not a replacement for task correctness or Arena scoring.

The common mean-time interface is:

mean_ms, metadata = benchmark_cuda_graph_or_events(
    fn,
    prepare_fn=None,
    warmup=10,
    repetition=100,
    target_ms=1.0,
    estimate_reps=5,
    max_graph_repeats=1000,
)

mean_ms is device milliseconds per invocation of fn. Suites whose scoring contract uses a median or percentile call benchmark_cuda_graph_or_events_samples() instead. It returns the same metadata and a list of per-invocation millisecond samples.

The callable must launch already-compiled device work. JIT compilation, module construction, and scratch/workspace sizing belong before the benchmark call. If the public operation returns newly allocated outputs, both sides must retain that same contract; otherwise both sides use caller-owned output buffers.

Stateful in-place kernels may provide prepare_fn. It runs on the active benchmark stream before each warmup and measured sample, but before the start event, so input restoration is ordered correctly and excluded from the kernel time. In this mode each graph replay contains one logical fn call; this prevents a later captured call from consuming state mutated by an earlier one. Output resets follow the same rule: they belong in prepare_fn, not in the captured/timed callable.

Graph-first measurement

For each fixed test case, the helper:

  1. Refuses to score when torch.cuda.is_available() is false. CPU wall-clock time is never substituted for kernel device time.
  2. Runs the requested warmup calls and synchronizes them.
  3. Captures and primes a small estimate graph, then measures one replay with GPU events.
  4. Rejects PyTorch's explicit empty-graph warning and independently rejects an effectively empty replay rather than reporting a fabricated near-zero time.
  5. Selects a bounded number of calls per graph so one replay targets roughly target_ms. This amortizes host launch overhead for short kernels.
  6. Captures and primes the final graph outside the reported sample set, replays it repetition times, and divides each replay's event time by the calls captured in that graph.
  7. For tasks that request a timed-run handle, exposes the exact captured output buffers and an additional replay of the same graph executable. Correctness checks poison or perturb those buffers, replay, and compare them with the eager/reference result. Automatic graph-to-Event fallback with a collector fails closed. Explicit Event observation is described below.

The start event, graph replay, and end event all run on the same side stream. This ordering is important: recording events on one stream while replaying on another can appear to time an empty stream.

Successful samples record at least:

benchmark_method: cuda_graph
benchmark_samples: 100
benchmark_effective_repeats: 80
benchmark_target_ms: 1.0
benchmark_max_repeats: 1000
benchmark_warmup: 10

GPU-event fallback

Some callables cannot be captured, for example because they synchronize the device, read a device scalar on the host, allocate capture-unsafe memory, or launch work on an incompatible stream. Capture failure, empty capture, and invalid replay timing fall back explicitly to eager GPU-event measurement:

benchmark_method: cuda_event_fallback
benchmark_fallback_reason: "cuda_graph_failed: RuntimeError: ..."
benchmark_effective_repeats: 1

Tasks may select Event timing for a known graph-capture incompatibility, or when the declared measured unit requires a fresh invocation of the public Python callable on every sample (for example, a wrapper that allocates and returns a new output). Pass use_cuda_graph=False with a stable fallback_reason, document why graph replay is not equivalent, and apply the same method and callable to baseline and candidate. A result is never silently changed to Event timing merely because graph timing is slower.

Graph after_sample receives the captured output after each reported replay. When one graph contains multiple calls, capture retains only the last returned output; graph replay also does not rerun Python dispatch or allocation. A single-call graph can make every replay's captured output observable, but it still measures graph replay rather than a fresh public call. Choose the method from the task contract, not from the apparent speedup. Disclose a method change and compare its before/after device times only under matched hardware, image, runtime, inputs and sampling settings. Device Events report GPU elapsed time; they do not turn host allocation or dispatch into CPU wall-clock timing.

Before accepting fallback, task harnesses should hoist host-side shape work, pointer-table creation, temporary allocation, and JIT setup out of fn, then directly launch the underlying kernel where that is part of the task's stable API. Do not remove a public wrapper's required allocation or dispatch merely to make its declared measured unit graph-capturable. A legacy HIP extension that hard-codes stream 0 is a legitimate example of an incompatible launch: CUDA/HIP Graph capture begins on a non-default side stream, while capturable PyTorch allocation/fill nodes can otherwise make a graph look non-empty even when the target kernel escaped to stream zero. HIP task harnesses therefore run a conservative source preflight. Every visible launch must use a stream obtained from PyTorch's current CUDA/HIP stream; a literal legacy stream, capture-unsafe synchronization/allocation, or an unverifiable launch construct classifies the baseline case as Event-only. For comparisons against a HIP reference, the reference source fixes this policy; candidate source cannot downgrade a graph-capable reference to Events.

Fallback still uses device events; it does not use Python, subprocess, or CPU wall-clock timing. Host and wall-time-only fields are rejected by the central performance parser.

For an explicit Event path, timed_run=TimedRun() exposes the return value from the last measured sample, after its ending GPU Event completes. It does not run a new untimed invocation to obtain that value. Its rerun() invokes the same eager callable on the measured stream, with prepare_fn before the call. This can allocate a new output and execute different Python dispatch decisions; it is not captured graph replay. The task must validate the measured output first and then validate the returned re-invocation output. Output observation alone is not a correctness verdict.

Collector metadata records benchmark_timed_run_kind: eager_callable for explicit Events and captured_graph for graph replay. The existing benchmark_method: cuda_event_fallback and fallback reason are unchanged. Automatic fallback from a failed/empty/invalid graph still rejects a requested collector; it does not silently switch the validation contract. Event timing must be selected explicitly when that is the task's declared methodology.

Cold-weight timing

benchmark_cuda_graph_cold_weights_samples() is an opt-in method for operators whose cost in a decode step comes from reading a weight from HBM. Under the default timing every sample reads the same weight, so after the first sample the weight sits in the L2 and the MALL. When prepare_fn restores or rotates inputs, each replay also holds a single call, so a decode-size operator that runs for a few microseconds is charged the whole fixed cost of a graph replay.

The task passes one zero-argument callable per weight copy. cold_weight_copy_count(weight_bytes) gives enough copies to pass 1 GiB in total, and at least 8:

from _aka_benchmark import (
    TimedRun, benchmark_cuda_graph_cold_weights_samples, cold_weight_copy_count,
)

copies = cold_weight_copy_count(weight_bytes, rotate_bytes=1 << 30, min_copies=8)
calls = [make_call(weights[i]) for i in range(copies)]
samples, metadata = benchmark_cuda_graph_cold_weights_samples(
    calls, warmup=20, repetition=100, prepare_fn=rotation, timed_run=TimedRun())

One CUDA graph calls every callable once, in order. Each sample is the replay time divided by the number of calls, so every call reads its weight from HBM and the fixed replay cost is shared by all calls. TimedRun.outputs is the list of per-call outputs, after_sample receives that list, and rerun_ms() returns the per-call time of one more replay. The metadata reports benchmark_method: cuda_graph_cold_weights, benchmark_calls_per_replay and benchmark_cold_weight_copies. The method has no event fallback, and AKA_BENCHMARK_FORCE_EVENT=1 makes it raise.

Every call needs its own weight copy and its own input buffer. Each weight copy is a separate draw from the task's initializer and stays fixed. prepare_fn runs once before the start event of each replay and draws a fresh, independent input into every call's buffer. With identical copies an implementation could read one copy for every call, so the weight stays in the caches. With identical copies and one shared input it could also compute one result and copy it to the other outputs. Both shortcuts pass the output checks.

A task that uses this method keeps the integrity checks of its default timing. It checks the output of every call against a reference for that call's input and weight copy, in the timed replays and in replays with fresh unseen inputs for every call. It also holds the reported time to the cost of the unseen inputs and checks that no weight copy changed.

Independent task workspaces

Task sources do not import AgentKernelArena's src package and do not carry copies of the canonical helper. For a schema-v3 kernel task, src/task_contract.py::render_workspace writes the evaluator and the timing helper into the run workspace as _aka_eval/_aka_benchmark.py, beside the resolved contract; solution/ is the only editable tree. The end-to-end serving tasks receive their serving client helpers from src/perf_helper_materialization.py. The materialized workspace is self-contained: the Python timing helper depends only on the standard library and PyTorch.

Generated helpers and protected evaluation inputs are covered by the harness integrity guard. A kernel task's candidate is the solution/ tree; every other file, including _aka_eval/, the contract, baseline and reference, is protected. See the task guide for the exact rules.

Normal optimization runs and quality_loop also snapshot the original task package's non-editable inputs before launching the optimizer. This includes case data such as session_cases.json, reference implementations, and helper files outside test directories. The snapshot is kept in framework memory and checked before evaluation and again before writing the final result. Editing, deleting, or renaming an original input rejects the run for every agent. The candidate boundary (solution/ for kernel tasks) identifies the implementation. Runtime outputs under build/, logs/, and perf/, environment caches, and generated result reports are not task inputs. New preparation files are allowed unless they match protected harness patterns, in which case the existing scratch-file removal policy applies. Cloned or image-seeded dependency trees retain the existing harness-pattern protection; this input snapshot is not a blanket source allowlist for those repositories.

Baseline and optimized fairness

The evaluator matches baseline and optimized cases by unique explicit ID first, then by unique parameters or shape. An ID establishes a pair but does not prove equal work: each pair must also have identical reported shape, params, and dtype fields. Changing or removing any of those fields prevents performance scoring, including for singleton/index-matched cases. Fields absent on both sides remain supported for legacy producers, with task inputs protected by the snapshot above. Nested metadata.params and metadata.dtype are normalized and these fields survive performance YAML round trips. Other diagnostic fields and adaptive timing repeat counts are not workload identity.

Workload mismatches retain measured timings, produce zero speedup, suppress comparison plots, and are recorded in workload_consistent and workload_mismatches in task_result.yaml.

Benchmark methods are then compared per matched case:

  • graph versus graph is comparable;
  • event fallback versus event fallback is comparable;
  • graph versus event fallback is retained as timing data but produces no speedup;
  • cold-weight graph (cuda_graph_cold_weights) is comparable only with cold-weight graph;
  • cold-cache graph (cuda_graph_cold_cache) is comparable only with the same cold-cache method, metric, eviction policy and eviction byte count;
  • different shapes may use different methods, provided each matched baseline/optimized pair uses the same exact method.

The baseline result fixes the timing policy before candidate measurement. If a baseline case succeeds with Graph but the candidate falls back to Events, the candidate timing remains visible for diagnosis but earns no performance score. Only a case that the baseline itself classified as Event-only can be scored as Event versus Event. The evaluator never collects or selects a candidate-driven alternate Event baseline.

Missing or unknown method metadata is not comparable and produces no speedup; every scored case must explicitly identify cuda_graph, cuda_event_fallback, cuda_graph_cold_weights or cuda_graph_cold_cache.

An aggregate mixed:... method string is never scored, even when the baseline and optimized strings are identical. It records only a set of methods and loses the shape-to-method mapping, so equality cannot prove that the same shapes used the same timer. The timing is retained with an ambiguous_mixed_aggregate mismatch reason.

This means a task can legitimately use graph timing for one shape and event fallback for another. The evaluator records method sets, per-case mismatch details, and benchmark_method_consistent in task_result.yaml. All benchmark_* metadata survives the baseline/optimized YAML round trip.

Serving wall-clock measurement

Tasks that declare evaluation.measurement.kind: serving do not time a kernel. Their unit of work is a fixed request set completed by a pinned benchmark client against a freshly started model server; the reported benchmark_method is serving_wall_clock, execution_time_ms is the client's wall duration, and metrics.output_tokens_per_s is the scored quantity. The protocol rejects a case whose completed requests, output tokens or input tokens differ from the manifest, or whose throughput does not equal tokens divided by duration. Graph-replay checks do not apply to this timer.

Final evaluation alternates baseline and candidate for at least three fresh pairs, each in its own clean container from the trusted task template. The per-case ratio is the median of the paired throughput ratios; several cases combine by geometric mean. serving_measurement.uncertainty keeps the ratio range and each side's repeat variation so a small median is not read as a gain. Before each performance action the container verifies the device is idle, and before final evaluation the worker container is swept of agent leftovers; both records are part of the result. Kernel tasks keep the device-timing rules above; mixed runs report the two groups separately with no combined average. See the e2e guide for the task-side contract.

Maintenance checks

Run:

make check-perf-helpers

src/tools/sync_perf_helpers.py audits committed task sources; it is not a GPU qualification. Schema-v3 kernel tasks (task.yaml) carry no benchmark code and are only counted. Every remaining schema-v2 task (config.yaml) must be a serving recipe (the exact bootstrap stub plus a hash-pinned workload) or a serving client whose scripts/evaluate.py imports _aka_serving; anything else fails the check instead of quietly using an undocumented timer. The check also fails when a generated helper copy (_aka_benchmark.py, _aka_serving*.py, _aka_eval/) is committed under tasks/.

Pull requests also run the CPU/mock unit suite and Python compilation audit in CI.

Event output-observation qualification

On 2026-09-15, Slurm job 139392 ran the three tests/test_gpu_graph_smoke.py checks on an MI355X (gfx950) with the pinned SGLang 0.5.19 qualification image on node crsuse2-m2m-001: all three passed, none skipped. Before qualification, the allocated device had 99.8% of its memory free and AMD-SMI reported no running processes. The previous helper rejected an explicit Event collector on the same GPU; the updated helper observed the actual measured output and validated eager re-invocation. See the runtime qualification record for image identities.

The HGEMM task also exercised all five original cases with the existing pinned SGLang 0.5.14 runtime (FlyDSL 0.2.2). Original and updated harnesses both passed baseline compile, correctness and performance actions using the same canonical helper. Each retained 100 Event samples, one call per sample and the original capture-unsafe reference reason. Updated results additionally recorded eager_callable, timed_output_correctness: PASS and replay_correctness: PASS for all five cases. These sequential runs verify timing boundaries and output checks; they do not establish a performance improvement. Action-level evidence is distinct from a full validator report (the predecessor of the QA auditor's qa_report.yaml). That separate HGEMM report was subsequently framework-finalized as PASS in the same job, with an implemented frozen initial candidate and no baseline diagnostic exemption.

Earlier job 139346 on node crsuse2-m2m-217 also produced successful functional reports, but a subsequent audit found external process/memory occupancy and other tasks failed with allocation/launch resource errors. Preserve those reports as historical functional evidence; all performance from that node is unqualified. Job 139392 explicitly excluded node217 and repeated the smoke, HGEMM boundary checks and the full task validator run (the predecessor of the QA audit) on the available-memory allocation described above. Neither sequential run establishes an optimization gain.